liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Experimental results using a three-layer skin model for diffuse reflectance spectroscopy
Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk instrumentteknik. Linköpings universitet, Tekniska högskolan. (Tomas Strömberg)
Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk instrumentteknik. Linköpings universitet, Tekniska högskolan. (Tomas Strömberg)ORCID-id: 0000-0003-4377-8544
Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk instrumentteknik. Linköpings universitet, Tekniska högskolan. (Tomas Strömberg)ORCID-id: 0000-0002-3454-6576
Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk instrumentteknik. Linköpings universitet, Tekniska högskolan. (Tomas Strömberg)ORCID-id: 0000-0001-6385-6760
2013 (engelsk)Inngår i: Optical Tomography and Spectroscopy of Tissue X / [ed] Bruce J. Tromberg, Arjun G. Yodh, Eva M. Sevick-Muraca, SPIE - International Society for Optical Engineering, 2013, s. 857834-1-857834-8Konferansepaper, Publicerat paper (Annet vitenskapelig)
Abstract [en]

We have previously presented an inverse Monte Carlo algorithm based on a three-layer semi-infinite skin model for analyzing diffuse reflectance spectroscopy (DRS) data. The algorithm includes pre-simulated Monte Carlo data for a range of physiologically relevant epidermal thicknesses and tissue scattering levels. The simulated photon pathlength distributions in each layer are stored and the absorption effect from tissue chromophores added in the post-processing. Recorded DRS spectra at source-detector distances of 0.4 and 1.2 mm were calibrated for the relative intensity between the two distances and matched to simulated spectra in a non-linear optimization algorithm. This study evaluates the DRS spectral fitting accuracy and presents data on the main output parameters; the tissue fraction of red blood cells and local oxygenation (SO2). As a reference, the microcirculatory perfusion (Perf) was measured simultaneously in the same probe using laser Doppler Flowmetry. Data were recorded on the volar forearm of three healthy subjects in a protocol involving a 5 min systolic occlusion. The DRS spectra were modeled with an rms-error < 2%. In two subjects, SO2 decreased during occlusion to <10%, and increased to above baseline after hyperemia, while Perf increased >7 times compared to baseline. In the third subject the SO2 decreased less during occlusion and increased to baseline values at hyperemia with only a 2-fold increase in Perf. The observed difference could be due to different microvascular beds being probed. It is concluded that integrating DRS and LDF enables new possibilities to deduce microcirculation status.

sted, utgiver, år, opplag, sider
SPIE - International Society for Optical Engineering, 2013. s. 857834-1-857834-8
Serie
Proceedings of SPIE, ISSN 0277-786X, E-ISSN 1996-756X ; 8578
Emneord [en]
Microcirculation, diffuse reflectance spectra, Monte Carlo simulations, skin modeling, laser Doppler flowmetry
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-97046DOI: 10.1117/12.2014323ISBN: 9780819493477 (tryckt)OAI: oai:DiVA.org:liu-97046DiVA, id: diva2:645355
Konferanse
Optical Tomography and Spectroscopy of Tissue X, 2 February 2013, San Francisco, California, USA
Forskningsfinansiär
VINNOVA, 2011-03074Tilgjengelig fra: 2013-09-04 Laget: 2013-09-04 Sist oppdatert: 2017-02-21bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Strömberg, TomasKarlsson, HannaFredriksson, IngemarLarsson, Marcus

Søk i DiVA

Av forfatter/redaktør
Strömberg, TomasKarlsson, HannaFredriksson, IngemarLarsson, Marcus
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 251 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf