liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A digital heterodyne laser interferometer for studying cochlear mechanics
Karolinska Institutet / Karolinska University Hospital, Stockholm, Sweden.
2009 (engelsk)Inngår i: Journal of Neuroscience Methods, ISSN 0165-0270, E-ISSN 1872-678X, Vol. 179, nr 2, s. 271-277Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Laser interferometry is the technique of choice for studying the smallest displacements of the hearing organ. For low intensity sound stimulation, these displacements may be below 1 nm. This cannot be reliably measured with other presently available techniques in an intact organ of Corti. In a heterodyne interferometer, light is projected against an object of study and motion of the target along the optical axis causes phase and frequency modulations of the back-reflected light. To recover object motion, the reflected light is made to interfere with a reference beam of artificially altered frequency, producing a beating signal. In conventional interferometers, this carrier signal is demodulated with analog electronics. In this paper, we describe a digital implementation of the technique, using direct carrier sampling. In order to obtain the necessary reference signal for demodulation we introduce an additional third light path. Together, this results in lower noise and reduces the cost of the system.

Within the hearing organ, different structures may move in different directions. It is therefore necessary to precisely measure the angle of incidence of the laser light, and to precisely localize the anatomical structure where the measurement is performed. Therefore, the interferometer is integrated with a laser scanning confocal microscope that permits us to map crucial morphometric parameters in each experiment. We provide key construction parameters and a detailed performance characterization. We also show that the system accurately measures the diminutive vibrations present in the apical turn of the cochlea during low-level sound stimulation.

sted, utgiver, år, opplag, sider
2009. Vol. 179, nr 2, s. 271-277
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-101061DOI: 10.1016/j.jneumeth.2009.02.002PubMedID: 19428537OAI: oai:DiVA.org:liu-101061DiVA, id: diva2:665156
Tilgjengelig fra: 2013-11-19 Laget: 2013-11-19 Sist oppdatert: 2018-01-11

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Fridberger, Anders

Søk i DiVA

Av forfatter/redaktør
Fridberger, Anders
I samme tidsskrift
Journal of Neuroscience Methods

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 3219 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf