liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A High Precision Method for Quantitative Measurements of Reactive Oxygen Species in Frozen Biopsies
Norwegian University of Science and Technology, Trondheim, Norway.
Umeå University, Sweden.
Linköpings universitet, Institutionen för fysik, kemi och biologi, Kemi. Linköpings universitet, Tekniska högskolan. Norwegian University of Science and Technology, Trondheim, Norway.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Diagnostikcentrum, Medicinsk teknik i Östergötland.
2014 (Engelska)Ingår i: PLOS ONE, E-ISSN 1932-6203, Vol. 9, nr 3Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective

An electron paramagnetic resonance (EPR) technique using the spin probe cyclic hydroxylamine 1-hydroxy-3-methoxycarbonyl-2,2,5,5-tetr​amethylpyrrolidine(CMH) was introduced as a versatile method for high precision quantification of reactive oxygen species, including the superoxide radical in frozen biological samples such as cell suspensions, blood or biopsies.

Materials and Methods

Loss of measurement precision and accuracy due to variations in sample size and shape were minimized by assembling the sample in a well-defined volume. Measurement was carried out at low temperature (150 K) using a nitrogen flow Dewar. The signal intensity was measured from the EPR 1st derivative amplitude, and related to a sample, 3-carboxy-proxyl (CP•) with known spin concentration.

Results

The absolute spin concentration could be quantified with a precision and accuracy better than ±10 µM (k = 1). The spin concentration of samples stored at −80°C could be reproduced after 6 months of storage well within the same error estimate.

Conclusion

The absolute spin concentration in wet biological samples such as biopsies, water solutions and cell cultures could be quantified with higher precision and accuracy than normally achievable using common techniques such as flat cells, tissue cells and various capillary tubes. In addition; biological samples could be collected and stored for future incubation with spin probe, and also further stored up to at least six months before EPR analysis, without loss of signal intensity. This opens for the possibility to store and transport incubated biological samples with known accuracy of the spin concentration over time.

Ort, förlag, år, upplaga, sidor
San Francisco: Public Library of Science , 2014. Vol. 9, nr 3
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-105262DOI: 10.1371/journal.pone.0090964ISI: 000332483600116PubMedID: 24603936OAI: oai:DiVA.org:liu-105262DiVA, id: diva2:705058
Tillgänglig från: 2014-03-14 Skapad: 2014-03-14 Senast uppdaterad: 2021-06-14Bibliografiskt granskad

Open Access i DiVA

fulltext(544 kB)411 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 544 kBChecksumma SHA-512
fe3b57ebc6964b1a771b5a57a8f687d4a00ff683fa289a60d8d133d3edc31098e55a5036ce90b5a2390411e797ccaaf4b3fa129fc11f715c390fe6c986216b90
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Person

Lindgren, MikaelGustafsson, Håkan

Sök vidare i DiVA

Av författaren/redaktören
Lindgren, MikaelGustafsson, Håkan
Av organisationen
KemiTekniska högskolanAvdelningen för radiologiska vetenskaperHälsouniversitetetMedicinsk teknik i Östergötland
I samma tidskrift
PLOS ONE
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 411 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 569 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf