liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Estimations of effective dose in X-ray examinations derived from information stored in PACS
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0002-8042-3833
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiologi. Linköpings universitet, Hälsouniversitetet. Jönköping County Hospital.
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0003-3352-8330
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.
Visa övriga samt affilieringar
2005 (Engelska)Ingår i: Radiological Protection in Transition: Proceedings of the XIV Regular Meeting of the Nordic Society for Radiation Protection, NSFS, Stockholm: Statens Strålskyddsinstitut , 2005, s. 175-178Konferensbidrag, Publicerat paper (Övrigt vetenskapligt)
Abstract [en]

Information about each X-ray examination, in a modern digitized X-ray department is generated and stored in a PACS. Appropriate conversion factors, e.g. E/DAP, can be applied to separate projections and summed to the total effective dose for each examination. The objectives of the work were (i) to investigate the accuracy and precision in the calculated effective dose (ii) to identify data for registration of (1) patient dose, (2) exposure data, and (3) patient information (iii) to make it possible to derive dose statistics on patient level for documentation of diagnostic standard doses, optimizations, constancy checks, and future epidemiological studies. The effective doses were calculated using Monte Carlo based computer programs or by using tabulations. Conversion factors were calculated for different levels of information and the individual effective dose was compared to the most precise estimation. The results suggest that the accuracy in the estimations of effective dose increases by added information about the patient (gender, size) and how the examination was performed.

Ort, förlag, år, upplaga, sidor
Stockholm: Statens Strålskyddsinstitut , 2005. s. 175-178
Serie
SSI-Rapport, ISSN 0282-4434 ; 2005:15
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-106272OAI: oai:DiVA.org:liu-106272DiVA, id: diva2:715316
Konferens
XIV Regular Meeting of the Nordic Society for Radiation Protection (NSFS), 27-31 August 2005, Rättvik, Sweden
Tillgänglig från: 2014-05-03 Skapad: 2014-05-03 Senast uppdaterad: 2015-03-20Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Link to paper

Personposter BETA

Gårdestig, MagnusHelmrot, EbbaSandborg, MichaelNilsson Althén, JonasBahar Gogani, JalilAlm Carlsson, GudrunPettersson, Håkan BL

Sök vidare i DiVA

Av författaren/redaktören
Gårdestig, MagnusHelmrot, EbbaSandborg, MichaelNilsson Althén, JonasBahar Gogani, JalilAlm Carlsson, GudrunPettersson, Håkan BL
Av organisationen
Medicinsk radiofysikHälsouniversitetetMedicinsk radiologi
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 177 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf