liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of high-dose-rate Ir-192 source strength measurements using equipment with traceability to different standards
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US. Swedish Radiation Safety Authority, Stockholm, Sweden.
Norwegian Radiation Protection Authority, Österås, Norway.
Swedish Radiation Safety Authority, Stockholm, Sweden.
Norwegian Radiation Protection Authority, Österås, Norway.
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Brachytherapy, ISSN 1538-4721, E-ISSN 1873-1449, Vol. 13, nr 4, s. 420-423Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE:

According to the American Association of Physicists in Medicine Task Group No. 43 (TG-43) formalism used for dose calculation in brachytherapy treatment planning systems, the absolute level of absorbed dose is determined through coupling with the measurable quantity air-kerma strength or the numerically equal reference air-kerma rate (RAKR). Traceability to established standards is important for accurate dosimetry in laying the ground for reliable comparisons of results and safety in adoption of new treatment protocols. The purpose of this work was to compare the source strength for a high-dose rate (HDR) (192)Ir source as measured using equipment traceable to different standard laboratories in Europe and the United States.

METHODS AND MATERIALS:

Source strength was determined for one HDR (192)Ir source using four independent systems, all with traceability to different primary or interim standards in the United States and Europe.

RESULTS:

The measured HDR (192)Ir source strengths varied by 0.8% and differed on average from the vendor value by 0.3%. Measurements with the well chambers were 0.5% ± 0.1% higher than the vendor-provided source strength. Measurements with the Farmer chamber were 0.7% lower than the average well chamber results and 0.2% lower than the vendor-provided source strength. All of these results were less than the reported source calibration uncertainties (k=2) of each measurement system.

CONCLUSIONS:

In view of the uncertainties in ion chamber calibration factors, the maximum difference in source strength found in this study is small and confirms the consistency between calibration standards in use for HDR (192)Ir brachytherapy.

Ort, förlag, år, upplaga, sidor
Elsevier, 2014. Vol. 13, nr 4, s. 420-423
Nyckelord [en]
Ir-192 HDR; Source strength determination; Calibration; Traceability
Nationell ämneskategori
Klinisk medicin
Identifikatorer
URN: urn:nbn:se:liu:diva-109245DOI: 10.1016/j.brachy.2014.01.002ISI: 000338175500016PubMedID: 24530343OAI: oai:DiVA.org:liu-109245DiVA, id: diva2:737165
Tillgänglig från: 2014-08-12 Skapad: 2014-08-11 Senast uppdaterad: 2017-12-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Carlsson Tedgren, Åsa

Sök vidare i DiVA

Av författaren/redaktören
Carlsson Tedgren, Åsa
Av organisationen
Centrum för medicinsk bildvetenskap och visualisering, CMIVAvdelningen för radiologiska vetenskaperHälsouniversitetetRadiofysikavdelningen US
I samma tidskrift
Brachytherapy
Klinisk medicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 194 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf