liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Highly accelerated aortic 4D flow MR imaging with variable-density random undersampling
University of Calif San Francisco, CA 94107 USA .
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Univ Calif San Francisco, CA 94107 USA.
University of Calif San Francisco, CA 94107 USA .
University of Calif San Francisco, CA 94107 USA .
Vise andre og tillknytning
2014 (engelsk)Inngår i: Magnetic Resonance Imaging, ISSN 0730-725X, E-ISSN 1873-5894, Vol. 32, nr 8, s. 1012-1020Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose: To investigate an effective time-resolved variable-density random undersampling scheme combined with an efficient parallel image reconstruction method for highly accelerated aortic 4D flow MR imaging with high reconstruction accuracy. Materials and Methods: Variable-density Poisson-disk sampling (vPDS) was applied in both the phase-slice encoding plane and the temporal domain to accelerate the time-resolved 3D Cartesian acquisition of flow imaging. In order to generate an improved initial solution for the iterative self-consistent parallel imaging method (SPIRiT), a sample-selective view sharing reconstruction for time-resolved random undersampling (STIRRUP) was introduced. The performance of different undersampling and image reconstruction schemes were evaluated by retrospectively applying those to fully sampled data sets obtained from three healthy subjects and a flow phantom. Results: Undersampling pattern based on the combination of time-resolved vPDS, the temporal sharing scheme STIRRUP, and parallel imaging SPIRiT, were able to achieve 6-fold accelerated 40 flow MRI with high accuracy using a small number of coils (N = 5). The normalized root mean square error between aorta flow waveforms obtained with the acceleration method and the fully sampled data in three healthy subjects was 0.04 +/- 0.02, and the difference in peak-systolic mean velocity was -0.29 +/- 2.56 cm/s. Conclusion: Qualitative and quantitative evaluation of our preliminary results demonstrate that time-resolved variable-density random sampling is efficient for highly accelerating 40 flow imaging while maintaining image reconstruction accuracy.

sted, utgiver, år, opplag, sider
Elsevier , 2014. Vol. 32, nr 8, s. 1012-1020
Emneord [en]
Undersampling; Random; Time-resolved; Parallel imaging; Flow; View sharing
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-110955DOI: 10.1016/j.mri.2014.05.004ISI: 000341068300006PubMedID: 24846341OAI: oai:DiVA.org:liu-110955DiVA, id: diva2:752298
Merknad

Funding Agencies|NIH [K25 EB014914, R01 NS059944]; VA MERIT Review grant; [VR 621-2013-6077]

Tilgjengelig fra: 2014-10-03 Laget: 2014-10-01 Sist oppdatert: 2017-12-05

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Dyverfeldt, Petter

Søk i DiVA

Av forfatter/redaktør
Dyverfeldt, Petter
Av organisasjonen
I samme tidsskrift
Magnetic Resonance Imaging

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 148 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf