EPR dosimetry intercomparison using smart phone touch screen glass
Istituto Superiore di Sanità, Rome, Italy.
Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France.
Institute of Radiation Protection, Helmholtz Zentrum München - German Research Center for Environmental Health, Neuherberg, Germany.
Dipartimento di Fisica e Chimica, Università di Palermo, Viale Delle Scienze, Palermo, Italy.
Vise andre og tillknytning
2014 (engelsk)Inngår i: Radiation and Environmental Biophysics, ISSN 0301-634X, E-ISSN 1432-2099, Vol. 53, nr 2, s. 311-320Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogeneous batch of glass and were stored in similar setting; for group B (formed by eight participants), samples came from different smart phones and stored in different settings of light and temperature. The calibration curves determined by the participants of group A had a small error and a critical level in the 0.37-0.40-Gy dose range, whereas the curves determined by the participants of group B were more scattered and led to a critical level in the 1.3-3.2-Gy dose range for six participants out of eight. Group A were able to assess the dose within 20 % for the lowest doses (< 1.5 Gy) and within 5 % for the highest doses. For group B, only the highest blind dose could be evaluated in a reliable way because of the high critical values involved. The results from group A are encouraging, whereas the results from group B suggest that the influence of environmental conditions and the intervariability of samples coming from different smart phones need to be further investigated. An alongside conclusion is that the protocol was easily transferred to participants making a network of laboratories in case of a mass casualty event potentially feasible.

sted, utgiver, år, opplag, sider
Springer-Verlag New York, 2014. Vol. 53, nr 2, s. 311-320
Emneord [en]
EPR dosimetry, Radiological emergency, Retrospective dosimetry, Glass
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-111969DOI: 10.1007/s00411-014-0533-xISI: 000334998200011PubMedID: 24671362OAI: oai:DiVA.org:liu-111969DiVA, id: diva2:762745
Tilgjengelig fra: 2014-11-12 Laget: 2014-11-12 Sist oppdatert: 2017-12-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Gustafsson, HåkanLund, EvaMarrale, Maurizio

Søk i DiVA

Av forfatter/redaktør
Gustafsson, HåkanLund, EvaMarrale, Maurizio
Av organisasjonen
I samme tidsskrift
Radiation and Environmental Biophysics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 205 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf