liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Validation of the CPAP Habit Index-5: A Tool to Understand Adherence to CPAP Treatment in Patients with Obstructive Sleep Apnea.
Linköpings universitet, Institutionen för medicin och hälsa, Omvårdnad. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Sinnescentrum, Neurofysiologiska kliniken US.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för samhällsmedicin. Linköpings universitet, Hälsouniversitetet.
University College London, UK.
Linköpings universitet, Institutionen för medicin och hälsa, Kardiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Hjärt- och Medicincentrum, Kardiologiska kliniken US.ORCID-id: 0000-0001-7431-2873
Vise andre og tillknytning
2014 (engelsk)Inngår i: Sleep Disorders, ISSN 2090-3545, E-ISSN 2090-3553, Vol. 2014, s. 1-9, artikkel-id 929057Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Long-term adherence to continuous positive airway pressure (CPAP) is low among patients with obstructive sleep apnea (OSA). The potential role of "habit" in sustaining adherence to CPAP use has not been studied. This study aimed to establish the relevance of habit to CPAP adherence, via validation of an adaptation of the Self-Report Habit Index (the CPAP Habit Index-5; CHI-5). Analyses focused on the homogeneity, reliability, and factor structure of the CHI-5 and, in line with theoretical predictions, its utility as a predictor of long-term CPAP adherence in middle-aged patients with OSA. A prospective longitudinal design was used. 117 patients with objectively verified OSA intended for CPAP treatment were recruited. Data was collected via clinical examinations, respiratory recordings, questionnaires, and CPAP devices at baseline, 2 weeks, 6 months, and 12 months. The CHI-5 showed satisfactory homogeneity interitem correlations (0.42-0.93), item-total correlations (0.58-0.91), and reliability ( α = 0.92). CHI-5 data at 6 months showed a one-factor solution and predicted 63% of variance in total CPAP use hours after 12 months. Based on the satisfactory measurement properties and the high amount of CPAP use variance it explained, the CHI-5 can be seen as a useful tool in clinical practice.

sted, utgiver, år, opplag, sider
2014. Vol. 2014, s. 1-9, artikkel-id 929057
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-115776DOI: 10.1155/2014/929057PubMedID: 24876975OAI: oai:DiVA.org:liu-115776DiVA, id: diva2:796512
Tilgjengelig fra: 2015-03-19 Laget: 2015-03-19 Sist oppdatert: 2017-12-04

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Broström, AndersNilsen, PerJohansson, PeterUlander, MartinArestedt, Kristofer

Søk i DiVA

Av forfatter/redaktør
Broström, AndersNilsen, PerJohansson, PeterUlander, MartinArestedt, Kristofer
Av organisasjonen
I samme tidsskrift
Sleep Disorders

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 521 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf