Comparison of Three Deep Brain Stimulation Lead Designs under Voltage and Current Modes
Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk instrumentteknik. Linköpings universitet, Tekniska fakulteten. (MINT)ORCID-id: 0000-0002-6896-1452
Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk instrumentteknik. Linköpings universitet, Tekniska fakulteten. (MINT)ORCID-id: 0000-0002-0012-7867
Linköpings universitet, Institutionen för medicinsk teknik, Biomedicinsk instrumentteknik. Linköpings universitet, Tekniska fakulteten. (MINT)
2015 (engelsk)Inngår i: WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2 / [ed] David A. Jaffray, Springer, 2015, Vol. 51, s. 1196-1199Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Since the introduction of deep brain stimulation (DBS) the technique has been dominated by Medtronic sys-tems. In recent years, new DBS systems have become available for patients, and some are in clinical trials. The present study aims to evaluate three DBS leads operated in either voltage or current mode. 3D finite element method (FEM) models were built in combination with a neuron model for this purpose. The axon diameter was set to D = 5 μm and simulations performed in both voltage (0.5-5 V) and current (0.5-5 mA) mode. The evaluation was achieved based on the distance from the lead for neural activation and the electric field (EF) extension at 0.1 V/mm. The results showed that the neural activation distance agrees well between the leads with an activation distance dif-ference less than 0.5 mm. The shape of the field at the 0.1 V/mm isopotential surface in 3D is mostly spherical in shape around the activated section of the steering lead.

sted, utgiver, år, opplag, sider
Springer, 2015. Vol. 51, s. 1196-1199
Serie
IFMBE Proceedings, ISSN 1680-0737 ; 51
Emneord [en]
deep brain stimulation (DBS), electrode design, finite element method (FEM), neuron model
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-120637DOI: 10.1007/978-3-319-19387-8_290ISI: 000381813000290ISBN: 978-3-319-19386-1 (tryckt)ISBN: 978-3-319-19387-8 (tryckt)OAI: oai:DiVA.org:liu-120637DiVA, id: diva2:847553
Konferanse
World congress on medical physics and biomedical engineering, Toronto, June 7-12, 2015
Forskningsfinansiär
Swedish Research Council, 621-2013-6078EU, FP7, Seventh Framework Programme, 305814Tilgjengelig fra: 2015-08-20 Laget: 2015-08-20 Sist oppdatert: 2017-02-03bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Alonso, FabiolaWårdell, KarinLatorre, Malcolm

Søk i DiVA

Av forfatter/redaktør
Alonso, FabiolaWårdell, KarinLatorre, Malcolm
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 838 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf