New dosimetry for childhood skin hemangioma treatments with Ra-226 needles or tubes
Karolinska University Hospital, Sweden; Karolinska Institute, Sweden.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Karolinska University Hospital, Sweden.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Karolinska University Hospital, Sweden.
2015 (Engelska)Ingår i: Radiotherapy and Oncology, ISSN 0167-8140, E-ISSN 1879-0887, Vol. 116, nr 1, s. 139-142Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: The Stockholm Hemangioma Cohort is important for evaluation of late effects after exposure to ionizing radiation during childhood. Dose estimates in this cohort were based on both measurements and calculations using an old treatment planning system. Methods: We compare previously published and calculated dose estimates with new ones, obtained by Monte Carlo simulations, which mimic the hemangioma treatments with Ra-226 needles and tubes. The distances between the Ra-226 sources and the thyroid and breasts, respectively, were reassessed. Result:. The Monte Carlo calculations showed significantly lower dose values than those obtained earlier. The differences depended both on the modeling of the sources and on further individualized distances from the sources. The mean value of the new calculated doses was 25% of the old breast doses and 46% of the old thyroid doses. Conclusion: New dosimetry for hemangioma treatments gives significantly lower organ doses for the few cases receiving the highest absorbed dose values. This implies that radiation risk estimates will increase and have to be recalculated. For retrospective studies it is now possible to calculate organ doses from radium treatments using modern treatment planning systems by modeling the source geometry carefully and apply the TG-43 formalism. It is important to be aware of the large uncertainties in calculated absorbed dose values.

Ort, förlag, år, upplaga, sidor
ELSEVIER IRELAND LTD , 2015. Vol. 116, nr 1, s. 139-142
Nyckelord [en]
Radium treatment; Hemangioma; Dosimetry; Organ doses; Children
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:liu:diva-122073DOI: 10.1016/j.radonc.2015.06.014ISI: 000360510400024PubMedID: 26104976OAI: oai:DiVA.org:liu-122073DiVA, id: diva2:885142
Anmärkning

Funding Agencies|European Commission [FP7-269553]; Swedish Radiation Safety Authority [SSM 2011-2499]

Tillgänglig från: 2015-12-18 Skapad: 2015-10-19 Senast uppdaterad: 2017-12-01

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Karlsson, MattiasCarlsson Tedgren, Åsa

Sök vidare i DiVA

Av författaren/redaktören
Karlsson, MattiasCarlsson Tedgren, Åsa
Av organisationen
Avdelningen för radiologiska vetenskaperMedicinska fakulteten
I samma tidskrift
Radiotherapy and Oncology
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 89 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf