liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
High-Resolution Laser Doppler Measurements of Microcirculation in the Deep Brain Structures: A Method for Potential Vessel Tracking.
Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation. Linköping University, Faculty of Science & Engineering. Linköping University, Center for Medical Image Science and Visualization (CMIV). (MINT)ORCID iD: 0000-0002-0012-7867
Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation. Linköping University, Faculty of Science & Engineering. University of Applied Sciences and Arts Northwestern Switzerland, Muttenz , Switzerland. (MINT)
Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation. Linköping University, Faculty of Science & Engineering. (MINT)
Linköping University, Department of Clinical and Experimental Medicine, Division of Neuro and Inflammation Science. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Anaesthetics, Operations and Specialty Surgery Center, Department of Neurosurgery.
2016 (English)In: Stereotactic and Functional Neurosurgery, ISSN 1011-6125, E-ISSN 1423-0372, Vol. 94, no 1, p. 1-9Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: Laser Doppler flowmetry (LDF) can be used to measure cerebral microcirculation in relation to stereotactic deep brain stimulation (DBS) implantations.

OBJECTIVE: To investigate the microcirculation and total light intensity (TLI) corresponding to tissue grayness in DBS target regions with high-resolution LDF recordings, and to define a resolution which enables detection of small vessels.

METHODS: Stereotactic LDF measurements were made prior to DBS implantation with 0.5-mm steps in the vicinity to 4 deep brain targets (STN, GPi, Vim, Zi) along 20 trajectories. The Mann-Whitney U test was used to compare the microcirculation and TLI between targets, and the measurement resolution (0.5 vs. 1 mm). The numbers of high blood flow spots along the trajectories were calculated.

RESULTS: There was a significant difference (p < 0.05) in microcirculation between the targets. High blood flow spots were present at 15 out of 510 positions, 7 along Vim and GPi trajectories, respectively. There was no statistical difference between resolutions even though both local blood flow and TLI peaks could appear at 0.5-mm steps.

CONCLUSIONS: LDF can be used for online tracking of critical regions presenting blood flow and TLI peaks, possibly relating to vessel structures and thin laminas along stereotactic trajectories.

Place, publisher, year, edition, pages
S. Karger, 2016. Vol. 94, no 1, p. 1-9
Keywords [en]
Deep brain stimulation · Laser Doppler flowmetry ·Stereotactic neurosurgery · Microcirculation · Navigation
National Category
Biomedical Laboratory Science/Technology Neurology
Identifiers
URN: urn:nbn:se:liu:diva-124691DOI: 10.1159/000442894ISI: 000373869900001PubMedID: 26795207OAI: oai:DiVA.org:liu-124691DiVA, id: diva2:902056
Note

Funding agencies:  Swedish Research Council [621-2013-6078]; Parkinson Foundation at Linkoping University; Swiss National Science Foundation [205321-135285]

Available from: 2016-02-10 Created: 2016-02-10 Last updated: 2017-11-30Bibliographically approved

Open Access in DiVA

fulltext(646 kB)535 downloads
File information
File name FULLTEXT01.pdfFile size 646 kBChecksum SHA-512
5cdee2b9d8c9c410c2aa23d5666cad0c815caef60d5d33d0a113136b5d418d78474429b883ac63a71a07d0d8044fd3f3eab1accfb300b60e64a8e4f9534d3a47
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Wårdell, KarinHemm-Ode, SimoneRejmstad, PeterZsigmond, Peter

Search in DiVA

By author/editor
Wårdell, KarinHemm-Ode, SimoneRejmstad, PeterZsigmond, Peter
By organisation
Biomedical InstrumentationFaculty of Science & EngineeringCenter for Medical Image Science and Visualization (CMIV)Division of Neuro and Inflammation ScienceFaculty of Medicine and Health SciencesDepartment of Neurosurgery
In the same journal
Stereotactic and Functional Neurosurgery
Biomedical Laboratory Science/TechnologyNeurology

Search outside of DiVA

GoogleGoogle Scholar
Total: 549 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 541 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf