liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Phase-contrast MRI volume flow - a comparison of breath held and navigator based acquisitions
Region Östergötland, Diagnostikcentrum, Fysiologiska kliniken ViN. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för radiologiska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping.ORCID-id: 0000-0003-3124-8044
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0003-1395-8296
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten.
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: BMC Medical Imaging, ISSN 1471-2342, E-ISSN 1471-2342, Vol. 16, nr 26Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

Background: Magnetic Resonance Imaging (MRI) 2D phase-contrast flow measurement has been regarded as the gold standard in blood flow measurements and can be performed with free breathing or breath held techniques. We hypothesized that the accuracy of flow measurements obtained with segmented phase-contrast during breath holding, and in particular higher number of k-space segments, would be non-inferior compared to navigator phase-contrast. Volumes obtained from anatomic segmentation of cine MRI and Doppler echocardiography were used for additional reference. Methods: Forty patients, five women and 35 men, mean age 65 years (range 53-80), were randomly selected and consented to the study. All underwent EKG-gated cardiac MRI including breath hold cine, navigator based free-breathing phase-contrast MRI and breath hold phase-contrast MRI using k-space segmentation factors 3 and 5, as well as transthoracic echocardiography within 2 days. Results: In navigator based free-breathing phase-contrast flow, mean stroke volume and cardiac output were 79.7 +/- 17.1 ml and 5071 +/- 1192 ml/min, respectively. The duration of the acquisition was 50 +/- 6 s. With k-space segmentation factor 3, the corresponding values were 77.7 ml +/- 17.5 ml and 4979 +/- 1211 ml/min (p = 0.15 vs navigator). The duration of the breath hold was 17 +/- 2 s. K-space segmentation factor 5 gave mean stroke volume 77.9 +/- 16.4 ml, cardiac output 5142 +/- 1197 ml/min (p = 0.33 vs navigator), and breath hold time 11 +/- 1 s. Anatomical segmentation of cine gave mean stroke volume and cardiac output 91.2 +/- 20.8 ml and 5963 +/- 1452 ml/min, respectively. Echocardiography was reliable in 20 of the 40 patients. The mean diameter of the left ventricular outflow tract was 20.7 +/- 1.5 mm, stroke volume 78.3 ml +/- 15.2 ml and cardiac output 5164 +/- 1249 ml/min. Conclusions: In forty consecutive patients with coronary heart disease, breath holding and segmented k-space sampling techniques for phase-contrast flow produced stroke volumes and cardiac outputs similar to those obtained with free-breathing navigator based phase-contrast MRI, using less time. The values obtained agreed fairly well with Doppler echocardiography while there was a larger difference when compared with anatomical volume determinations using SSFP (steady state free precession) cine MRI.

Ort, förlag, år, upplaga, sidor
BioMed Central, 2016. Vol. 16, nr 26
Nyckelord [en]
Phase-contrast flow; Magnetic resonance imaging; Segmentation; 2D Doppler echocardiography
Nationell ämneskategori
Klinisk medicin
Identifikatorer
URN: urn:nbn:se:liu:diva-127432DOI: 10.1186/s12880-016-0128-xISI: 000372901200001PubMedID: 27021353OAI: oai:DiVA.org:liu-127432DiVA, id: diva2:925257
Anmärkning

Funding Agencies|Swedish Heart and Lung Foundation [20120449, 20140398]; Region of Ostergotland [281281]; European Union FP 7 [223615]; Medical Research Council of Southeast Sweden [88731, 157921]

Tillgänglig från: 2016-05-01 Skapad: 2016-04-26 Senast uppdaterad: 2018-03-20Bibliografiskt granskad

Open Access i DiVA

fulltext(690 kB)199 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 690 kBChecksumma SHA-512
5cde23f30b27bf01f543a385a6b662bfb0be47b399042f903d2468646efa4e3425f6312553da7b1e451b396ec56068d83158283143822b38c1b149b4e8e35bec
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Kihlberg, JohanEbbers, TinoLindström, LenaCarlhäll, CarljohanEngvall, Jan

Sök vidare i DiVA

Av författaren/redaktören
Kihlberg, JohanEbbers, TinoLindström, LenaCarlhäll, CarljohanEngvall, Jan
Av organisationen
Fysiologiska kliniken ViNCentrum för medicinsk bildvetenskap och visualisering, CMIVAvdelningen för radiologiska vetenskaperMedicinska fakultetenRöntgenkliniken i LinköpingAvdelningen för kardiovaskulär medicinFysiologiska kliniken US
I samma tidskrift
BMC Medical Imaging
Klinisk medicin

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 199 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 744 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf