Simple design for Seebeck measurement of bulk sample by 2-probe method concurrently with electrical resistivity by 4-probe method in the temperature range 300-1000 K
Indian Institute Technology, India; Science and Engn Research Board, India.
Linköpings universitet, Institutionen för fysik, kemi och biologi, Tunnfilmsfysik. Linköpings universitet, Tekniska fakulteten.
2016 (engelsk)Inngår i: Measurement, ISSN 0263-2241, E-ISSN 1873-412X, Vol. 91, s. 613-619Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

The 4-probe method has so far been the most popular method for concurrent measurement of Seebeck coefficient and electrical resistivity of bulk samples. However, for Seebeck measurement with higher accuracy, the 2-probe method is becoming preferred over 4-probe method. The problem with the previous apparatus designs is that they do not allow 2-probe arrangement for Seebeck measurement simultaneously with linear 4-probe arrangement for electrical resistivity measurement. So, the challenge is find a design where two different probe arrangements become possible at the same time in a single measurement run. Here, we report design and fabrication of an apparatus that allows Seebeck measurement by 2-probe method concurrently with electrical resistivity by 4-probe method of bar and disc samples in the temperature range from 300 to 1000 K. The uniqueness of the present design is that it does not require heating the entire sample chamber for temperature dependent measurements. This is because a small cylindrical furnace inside the sample chamber is used to control the sample background temperature. This internal furnace arrangement results in readily achievable set temperature with desired uniformity. Thus, it allows faster thermoelectric evaluation of samples. The design includes several preventive steps to negate the effect of off-axial heat flows on the measurement accuracy. The measurement error in Seebeck coefficient and electrical resistivity of PbTe sample is estimated to be smaller than 5%. (C) 2016 Elsevier Ltd. All rights reserved.

sted, utgiver, år, opplag, sider
ELSEVIER SCI LTD , 2016. Vol. 91, s. 613-619
Emneord [en]
Measurement; Seebeck coefficient; 2-probe method; Electrical resistivity; 4-probe method
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-130366DOI: 10.1016/j.measurement.2016.05.104ISI: 000379507400068OAI: oai:DiVA.org:liu-130366DiVA, id: diva2:952823
Merknad

Funding Agencies|University Grant Commission (UGC) of India through UGC (NET); Council of Scientific and Industrial Research (CSIR) India through CSIR (NET); Eurostars project [E!8892 T-to-Power]; European Research Council under the European Communitys Seventh Framework Programme/ERC - Belgium [335383]

Tilgjengelig fra: 2016-08-15 Laget: 2016-08-05 Sist oppdatert: 2017-11-28

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Paul, Biplab

Søk i DiVA

Av forfatter/redaktør
Paul, Biplab
Av organisasjonen
I samme tidsskrift
Measurement

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 165 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf