liu.seSearch for publications in DiVA
Change search
ReferencesLink to record
Permanent link

Direct link
Discrepancies in recommended criteria for grading of carotid stenosis with ultrasound
Karolinska Institute, Sweden; Karolinska University Hospital, Sweden.
Sahlgrens University Hospital, Sweden.
Karolinska University Hospital, Sweden.
Blekingesjukhuset, Sweden.
Show others and affiliations
2016 (English)In: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 36, no 4, 326-329 p.Article in journal (Refereed) Published
Abstract [en]

The accuracy of duplex ultrasound for grading of internal carotid artery stenosis has been widely tested and shown to be high. However, different methods for measurement of the degree of carotid stenosis with the golden standard conventional angiography have been used in the different studies. This, together with other factors, has led to some confusion regarding the relation between the ultrasonographically measured flow velocity and the angiographically measured degree of stenosis. The ultrasound criteria that are used in Sweden (and in Germany) differ in an important way from the criteria recommended in North America and the United Kingdom for the same degree of angiographic stenoses. Possible reasons for the discrepancies are discussed in this article. The authors recommend absolute agreement locally whether ECST or NASCET criteria shall be used in the communication between radiologists, clinical physiologists, vascular surgeons, neurologists and other physicians involved in patient management decisions. Angle-dependent ultrasound criteria should be used and flow velocity measurements with ultrasound should be combined with assessment of plaque burden on 2D picture.

Place, publisher, year, edition, pages
WILEY-BLACKWELL , 2016. Vol. 36, no 4, 326-329 p.
Keyword [en]
angiography; carotid stenosis; ultrasonography
National Category
Medical Laboratory and Measurements Technologies
Identifiers
URN: urn:nbn:se:liu:diva-132085DOI: 10.1111/cpf.12236ISI: 000383447000012PubMedID: 26046306OAI: oai:DiVA.org:liu-132085DiVA: diva2:1038374
Available from: 2016-10-18 Created: 2016-10-17 Last updated: 2016-10-18

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Zachrisson, Helene
By organisation
Division of Cardiovascular MedicineFaculty of Health SciencesDepartment of Clinical Physiology in LinköpingCenter for Medical Image Science and Visualization (CMIV)
In the same journal
Clinical Physiology and Functional Imaging
Medical Laboratory and Measurements Technologies

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 9 hits
ReferencesLink to record
Permanent link

Direct link