Clinical feasibility of 3D-QALAS - Single breath-hold 3D myocardial T1 and T2-mapping
Linköping University, Department of Medical and Health Sciences, Division of Cardiovascular Medicine. Linköping University, Faculty of Medicine and Health Sciences. Linköping University, Center for Medical Image Science and Visualization (CMIV).
Linköping University, Department of Medical and Health Sciences, Division of Cardiovascular Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Heart and Medicine Center, Department of Clinical Physiology in Linköping. Linköping University, Center for Medical Image Science and Visualization (CMIV). SyntheticMR AB, Linkoping, Sweden.
Linköping University, Department of Medical and Health Sciences, Division of Cardiovascular Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Heart and Medicine Center, Department of Clinical Physiology in Linköping. Linköping University, Center for Medical Image Science and Visualization (CMIV).
Linköping University, Department of Medical and Health Sciences, Division of Cardiovascular Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Heart and Medicine Center, Department of Clinical Physiology in Linköping. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0003-2198-9690
Show others and affiliations
2017 (English)In: Magnetic Resonance Imaging, ISSN 0730-725X, E-ISSN 1873-5894, Vol. 38, 13-20 p.Article in journal (Refereed) Published
Abstract [en]

Purpose: To investigate the in-vivo precision and clinical feasibility of 3D-QALAS- a novel method for simultaneous three-dimensional myocardial T1- and T2-mapping. Methods: Ten healthy subjects and 23 patients with different cardiac pathologies underwent cardiovascular 3 T MRI examinations including 3D-QALAS, MOLLI and T2-GraSE acquisitions. Precision was investigated in the healthy subjects between independent scans, between dependent scans and as standard deviation of consecutive scans. Clinical feasibility of 3D-QALAS was investigated for native and contrast enhanced myocardium in patients. Data were analyzed using mean value and 95% confidence interval, Pearson correlation, Paired t-tests, intraclass correlation and Bland-Altman analysis. Results: Average myocardial relaxation time values and SD from eight repeated acquisitions within the group of healthy subjects were 1178 +/- 18.5 ms (1.6%) for T1 with 3D-QALAS, 52.7 +/- 1.2 ms (23%) for T2 with 3D-QALAS, 1145 +/- 10.0 ms (0.9%) for Tl with MOLLI and 49.2 +/- 0.8 ms (1.6%) for T2 with GraSE. Myocardial Tl and T2 relaxation times obtained with 3D-QALAS correlated very well with reference methods; MOW for T1 (r = 0.994) and T2-GraSE for T2 (r = 0.818) in the 23 patients. Average native/post-contrast myocardial Tl values from the patients were 1166.2 ms/411.8 ms for 3D-QALAS and 1174.4 ms/438.9 ms for MOW. Average native myocardial T2 values from the patients were 53.2 ms for 3D-QAIAS and 54.4 ms for T2-GraSE. Conclusions: Repeated independent and dependent scans together with the intra-scan repeatability, demonstrated all a very good precision for the 3D-QALAS method in healthy volunteers. This study shows that 3D T1 and T2 mapping in the left ventricle is feasible in one breath hold for patients with different cardiac pathologies using 3D-QALAS. (C) 2016 Elsevier Inc. All rights reserved.

Place, publisher, year, edition, pages
ELSEVIER SCIENCE INC , 2017. Vol. 38, 13-20 p.
Keyword [en]
T1 mapping; T2 mapping; Myocardium; Precision; 3D-QALAS; Validation
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-136856DOI: 10.1016/j.mri.2016.12.014ISI: 000398008700003PubMedID: 27998745OAI: oai:DiVA.org:liu-136856DiVA: diva2:1092114
Note

Funding Agencies|Swedish Heart-Lung Foundation [20120449, 20140398]; Swedish Research Council [2014-6191]

Available from: 2017-04-30 Created: 2017-04-30 Last updated: 2017-05-19

Open Access in DiVA

The full text will be freely available from 2017-12-18 14:49
Available from 2017-12-18 14:49

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Kvernby, SofiaWarntjes, Marcel Jan BertusEngvall, JanCarlhäll, CarljohanEbbers, Tino
By organisation
Division of Cardiovascular MedicineFaculty of Medicine and Health SciencesCenter for Medical Image Science and Visualization (CMIV)Department of Clinical Physiology in Linköping
In the same journal
Magnetic Resonance Imaging
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 75 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf