Deep brain stimulation: software for patient-specific electric field simulations
Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. (MINT)ORCID iD: 0000-0002-0012-7867
Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. (MINT)ORCID iD: 0000-0003-4910-0291
Linköping University, Department of Biomedical Engineering, Division of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. (MINT)ORCID iD: 0000-0002-6896-1452
2017 (English)Conference paper, Poster (with or without abstract) (Refereed)
Abstract [en]

Introduction

The electric field (EF) around the active deep brain stimulation (DBS) contact is of interest for optimizing the therapeutic effect. We have previously developed a method for simulation and visualization of the EF. The aim of the project is to improve the software for quick and user friendly simulations.  

Methods

The ELMA software for brain model creation has been improved by adding quick ROI selection and transformation to an electrical conductivity map based on tissue classification through multiple slices of the preoperative MRI. These data are used as input for Comsol Multiphysics simulations of the EF. Two points along the position of the lead, as seen in the postoperative images, are used for correct placement in the brain model. Multiple DBS lead models are pre-programmed. The active contact and amplitude are user-selected.

Results

After a simulation the result is visualized with a user defined isolevel or isosurface superimposed on the patients preoperative MRI. An example is shown in Fig. 1. The 3389 lead is places in zona inserta (Zi) and contact 1 activated with 2 and 4 V respectively. An isolevel of 0.2 V/mm is used corresponding to a ~ 3-4 µm axon diameter when using a pulse length of 60 µs. More examples will be presented at the meeting.

Conclusion

The software for patient-specific simulations of EF around DBS electrodes has been improved for quicker simulations and more DBS leads. As a next step user friendly Apps will be implemented.

Place, publisher, year, edition, pages
2017.
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:liu:diva-139879OAI: oai:DiVA.org:liu-139879DiVA, id: diva2:1134561
Conference
World Society for Stereotactic and Functional Neurosurgery, 17th Quadrennial meeting, Berlin June 26-29, 2017
Available from: 2017-08-21 Created: 2017-08-21 Last updated: 2020-12-09

Open Access in DiVA

No full text in DiVA

Authority records

Wårdell, KarinJohansson, JohannesAlonso, Fabiola

Search in DiVA

By author/editor
Wårdell, KarinJohansson, JohannesAlonso, Fabiola
By organisation
Division of Biomedical EngineeringFaculty of Science & Engineering
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 198 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf