Characteristics of a First-Generation X-Ray System
Maastricht University, Netherlands.ORCID iD: 0000-0002-7104-7127
Maastricht University, Netherlands.
Maastricht University, Netherlands.
Maastricht University, Netherlands.
Show others and affiliations
2011 (English)In: Radiology, ISSN 0033-8419, E-ISSN 1527-1315, Vol. 259, no 2, p. 534-539Article in journal (Refereed) Published
Abstract [en]

Purpose: To compare the antiquated x-ray system of Hoffmans and van Kleef (circa 1896) with modern x-ray equipment in terms of radiation dose, x-ray beam properties, image quality, and electrical parameters. Materials and Methods: The antiquated x-ray system consisted of a Ruhmkorff inductor, battery, and Crookes tube. The radiation dose rate, x-ray beam properties, and electrical characteristics of this system were determined. A modern computed radiography plate was used to compare images of a hand specimen obtained by using the antiquated system with images obtained by using the modern system. Results: A peak voltage of 73 kV was obtained with an 8-V battery. With Crookes tube number 9, the half-value layer of the generated x-rays was 0.56 mm Al. Pinhole images showed that the x-rays originated from an extended area of the glass wall, causing image blurring. When measured on the skin of a hand specimen, the radiation dose of the antiquated system was about 10 times greater than that of the modern system for the same detector signal. The estimated skin dose was about 74 mGy for the antiquated system and 0.05 mGy for the modern system. The corresponding exposure times were 90 minutes and 21 msec. Conclusion: Radiation dose and exposure time of the antiquated system were greater than those of the modern system by about three and five orders of magnitude, respectively. Images of the hand specimen obtained with the antiquated system were severely blurred but were still awe inspiring, considering the simplicity of the system. (C)RSNA, 2011

Place, publisher, year, edition, pages
Radiological Society of North America (RSNA) , 2011. Vol. 259, no 2, p. 534-539
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-141464DOI: 10.1148/radiol.11101899ISI: 000289667300028PubMedID: 21411750OAI: oai:DiVA.org:liu-141464DiVA, id: diva2:1145752
Note

Funding Agencies|Bayer Schering Pharma; Boston Scientific; GE Healthcare

Available from: 2017-09-29 Created: 2017-09-29 Last updated: 2017-10-09

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Kemerink, MartijnKemerink, Gerrit J.
In the same journal
Radiology
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 32 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf