liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Functional CuO Microstructures for Glucose Sensing
University of Sindh, Pakistan.
Luleå University of Technology, Sweden.
University of Sindh, Pakistan.
University of Sindh, Pakistan.
Show others and affiliations
2018 (English)In: Journal of Electronic Materials, ISSN 0361-5235, E-ISSN 1543-186X, Vol. 47, no 2, p. 1519-1525Article in journal (Refereed) Published
Abstract [en]

CuO microstructures are produced in the presence of water-soluble amino acids by hydrothermal method. The used amino acids include isoleucine, alpha alanine, and arginine as a soft template and are used for tuning the morphology of CuO nanostructures. The crystalline and morphological investigations were carried out by x-ray diffraction (XRD) and scanning electron microscopy techniques. The XRD study has shown that CuO material obtained in the presence of different amino acids is of high purity and all have the same crystal phase. The CuO microstructures prepared in the presence of arginine were used for the development of sensitive and selective glucose biosensor. The linear range for the glucose detection are from 0.001 mM to 30 mM and limit of detection was found to be 0.0005 mM. The sensitivity was estimated around 77 mV/decade. The developed biosensor is highly selective, sensitive, stable and reproducible. The glucose biosensor was used for the determination of real human blood samples and the obtained results are satisfactory. The CuO material is functional therefore can be capitalized in wide range of applications such as lithium ion batteries, all oxide solar cells and supercapacitors.

Place, publisher, year, edition, pages
SPRINGER , 2018. Vol. 47, no 2, p. 1519-1525
Keywords [en]
CuO microstructures; amino acids; potentiometric; glucose biosensor
National Category
Materials Chemistry
Identifiers
URN: urn:nbn:se:liu:diva-144553DOI: 10.1007/s11664-017-5936-4ISI: 000419791800077OAI: oai:DiVA.org:liu-144553DiVA, id: diva2:1178289
Note

Funding Agencies|National Natural Science Foundation of China [21550110195]; Chinese Academy of Sciences Presidents International Fellowship Initiative [2015PM010]

Available from: 2018-01-29 Created: 2018-01-29 Last updated: 2018-01-29

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Search in DiVA

By author/editor
Willander, Magnus
By organisation
Physics and ElectronicsFaculty of Science & Engineering
In the same journal
Journal of Electronic Materials
Materials Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 866 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf