liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A cool response: the influence of ambient temperature on capillary refill time
Linköping University, Department of Clinical and Experimental Medicine, Division of Neuro and Inflammation Science. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Local Health Care Services in Central Östergötland, Department of Emergency Medicine in Linköping.
Linköping University, Department of Medical and Health Sciences, Division of Drug Research. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Local Health Care Services in Central Östergötland, Department of Emergency Medicine in Linköping.
Region Östergötland, Center for Disaster Medicine and Traumatology. Linköping University, Department of Clinical and Experimental Medicine, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0003-3708-1978
Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Disaster Medicine and Traumatology. Linköping University, Department of Clinical and Experimental Medicine, Division of Surgery, Orthopedics and Oncology.ORCID iD: 0000-0003-1383-375X
Show others and affiliations
2018 (English)In: Journal of Biophotonics, ISSN 1864-063X, E-ISSN 1864-0648, Vol. 11, no 6Article in journal (Refereed) Published
Abstract [en]

Objective

To describe the effect of low ambient temperature on skin temperature and capillary refill (CR) time in forehead, sternum and finger pulp.

Methods

An observational, nonrandomized experimental study on 15 healthy subjects (6 females) in a cold room (8°C). Outcome measures were skin temperature and quantified CR test after application of a standardized blanching pressure (9 N/cm2) using digital photographic polarization spectroscopy to generate CR times.

Results

The finger pulp showed marked temperature fall and prolonged CR times (>10 seconds). The CR registrations of the forehead and sternum were more comparable to curves observed in a control material at room temperature, and skin temperature falls were less marked. CR times were not prolonged in forehead measurements. At the sternum, some individuals showed CR times beyond guideline recommendations despite only a marginal reduction in skin temperature.

Conclusions

Low ambient temperature is a strong independent factor for CR time at peripheral sites. Reservation about sternum as a site of measurement is warranted since cold provocation produced prolonged CR times in some individuals. We found that the forehead is the most thermostable of the 3 sites and thus the preferred site to avoid ambient temperature artifact in measuring CR time.

Place, publisher, year, edition, pages
Wiley-VCH Verlagsgesellschaft, 2018. Vol. 11, no 6
National Category
Atom and Molecular Physics and Optics
Research subject
Disaster Medicine
Identifiers
URN: urn:nbn:se:liu:diva-145527DOI: 10.1002/jbio.201700371ISI: 000434641700017PubMedID: 29384267OAI: oai:DiVA.org:liu-145527DiVA, id: diva2:1187475
Note

Funding agencies: Socialstyrelsen; Region Ostergotland

Available from: 2018-03-05 Created: 2018-03-05 Last updated: 2020-04-01Bibliographically approved
In thesis
1. To See or Not to See: A Study on Capillary Refill
Open this publication in new window or tab >>To See or Not to See: A Study on Capillary Refill
2020 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Background: Assessment of the critically ill is traditionally based on vital signs (blood pressure, pulse, respiratory rate, temperature and level of consciousness). Altered vital signs are, however, late indicators of deranged hemodynamics pointing to a need for additional, more sensitive markers of circulatory compromise. In the beginning of the 20th century, the capillary refill (CR) time evolved as a possible, non-invasive adjunct to early prediction of the outcome in the critically ill. The manoeuvre entails application of blanching pressure on the skin of the finger pulp or sternum for 5 seconds. After release of the pressure, the observer estimates time in seconds for the skin to return to original colour. This time is hypothesized to reflect the dynamics of the microcirculation and its possible connection with hemodynamics. In the 1980s the “normal capillary refill time” was set to < 2 seconds and later extended to 3 seconds, without a clear scientific foundation. Naked-eye estimations of CR time met increasing scepticism in the 1990s due to subjectivity and poor prognostic value for shock or death. Several basic traits, such as age and sex, as well as ambient temperature, were also shown to independently influence the CR time. Various methods have evolved with the capability to measure CR time quantitatively, one of which is Polarisation Spectroscopy Imaging (PSI). PSI measures the Red Blood Cell (RBC) concentration in tissue (e.g. the skin) and can be used to measure CR time.

Objectives: The purpose of this study was to establish basic characteristics for quantified CR (qCR), identify possible influencing factors in healthy subjects and to investigate how this relates to current practice. We also sought to identify technical demands for transfer of the technique into clinical studies. In paper I we analysed the (qCR) time characteristics at 5 different skin sites (forehead, sternum, volar forearm, finger pulp and dorsum finger). The objective of paper II was to investigate the inter- and intra-observer variability of naked eye CR assessments of different professions, nurses, doctors and secretaries (representing laymen). In paper III we observed the effect of low ambient temperature on the qCR time in different skin sites. In paper IV, we transferred the equipment from a laboratory to a clinical setting in the Emergency Department (ED) for application on potentially critically ill patients. In this study we evaluated the most important factors determining a reliable data collection and influencing the amount of data possible to analyse.

Methods: qCR time was measured in a total of 38 volunteers and 10 patients in different skin sites (2-5 skin sites) at different ambient temperatures. PSI (TiVi 600 and 700, WheelsBridge AB, Linköping, Sweden) was used to determine the rapid temporal changes in RBC concentration in skin during the CR manoeuvre. Films using a range of the first measurements from paper I were shown for assessment to 48 observers working in the ED.

Results: In paper I we could delineate qCR curves and suggest 2 possible equivalents to the naked-eye observed CR time which we named Time to Return to Baseline 1 (tRtB1) and Time to Peak (tpk). We demonstrated differences in qCR-curves depending on skin site and possibly due to skin temperature. In paper II we showed a poor inter- and intra-observer reproducibility in visually estimating the CR time regardless of profession (clinicians or laymen). Paper III demonstrated a rapid effect of ambient temperature on qCR time in peripheral skin sites such as finger pulp. The forehead, regarded as a more central skin site was the most temperature stable site and showed least variability in qCR time as determined using tRtB1. Paper IV, a study on patients in an ED setting, yielded assayable data in 80% of the measurements. We identified critical performance parameters to address in the further development of a more robust, easy-to-use device for future validation of the possible relevance of qCR in patient triage and monitoring.

Conclusions: CR time can be quantified using PSI. Quantified CR time demonstrated a large variability between different skin sites, specifically, skin temperature was shown to be an important factor influencing qCR time, particularly at the fingertip. Naked-eye estimates of CR time were highly variable, both within and between observers. Agreement between quantified CR time and naked-eye estimates was poor. The prototypic PSI technique was feasible in a clinical setting and, with further improvements, clinical evaluation of qCR in relation to relevant patient outcomes will be possible.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2020. p. 47
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1732
National Category
Medical Laboratory Technologies
Identifiers
urn:nbn:se:liu:diva-164907 (URN)10.3384/diss.diva-164907 (DOI)9789179298913 (ISBN)
Public defence
2020-05-05, Berzeliussalen, Building 463, Campus US, Linköping, 09:00 (English)
Opponent
Supervisors
Available from: 2020-04-01 Created: 2020-04-01 Last updated: 2025-02-09Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Toll John, RaniHenricson, JoakimJunker, JohanJonson, Carl-OscarNilsson, GertBjörk Wilhelms, DanielAnderson, Chris D

Search in DiVA

By author/editor
Toll John, RaniHenricson, JoakimJunker, JohanJonson, Carl-OscarNilsson, GertBjörk Wilhelms, DanielAnderson, Chris D
By organisation
Division of Neuro and Inflammation ScienceFaculty of Medicine and Health SciencesDepartment of Emergency Medicine in LinköpingDivision of Drug ResearchCenter for Disaster Medicine and TraumatologyDivision of Surgery, Orthopedics and OncologyBiomedical InstrumentationThe Institute of TechnologyDivision of Cell BiologyDepartment of Dermatology and Venerology
In the same journal
Journal of Biophotonics
Atom and Molecular Physics and Optics

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 4794 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf