liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Knitted Carbon-Nanotube-Sheath/Spandex-Core Elastomeric Yarns for Artificial Muscles and Strain Sensing
Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, University of Wollongong, Wollongong, NSW, Australia; Illawarra Health and Medical Research Institute (IHMRI), University of Wollongong, Wollongong, Australia.
Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, University of Wollongong, Wollongong, NSW, Australia.
Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, University of Wollongong, Wollongong, NSW, Australia.
Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, University of Wollongong, Wollongong, NSW, Australia.
Show others and affiliations
2016 (English)In: ACS Nano, ISSN 1936-0851, E-ISSN 1936-086X, Vol. 10, p. 9129-9135Article in journal (Refereed) Published
Abstract [en]

Highly stretchable, actuatable, electrically conductive knitted textiles based on Spandex (SPX)/CNT (carbon nanotube) composite yarns were prepared by an integrated knitting procedure. SPX filaments were continuously wrapped with CNT aerogel sheets and supplied directly to an interlocking circular knitting machine to form the three-dimensional electrically conductive and stretchable textiles. By adjusting the SPX/CNT feed ratio, the fabric electrical conductivities could be tailored in the range of 870 to 7092 S/m. The electrical conductivity depended on tensile strain, with a linear and largely hysteresis-free resistance change occurring on loading and unloading between 0 and 80% strain. Electrothermal heating of the stretched fabric caused large tensile contractions of up to 33%, and generated a gravimetric mechanical work capacity during contraction of up to 0.64 kJ/kg and a maximum specific power output of 1.28 kW/kg, which far exceeds that of mammalian skeletal muscle. The knitted textile provides the combination of strain sensing and the ability to control dimensions required for smart clothing that simultaneously monitors the wearer's movements and adjusts the garment fit or exerts forces or pressures on the wearer, according to needs. The developed processing method is scalable for the fabrication of industrial quantities of strain sensing and actuating smart textiles.

Place, publisher, year, edition, pages
American Chemical Society (ACS), 2016. Vol. 10, p. 9129-9135
Keywords [en]
actuators; carbon nanotube; sensors; smart textiles; Spandex
National Category
Medical and Health Sciences Materials Chemistry
Identifiers
URN: urn:nbn:se:liu:diva-151317DOI: 10.1021/acsnano.6b04125ISI: 000386423600012PubMedID: 27607843Scopus ID: 2-s2.0-84993982644OAI: oai:DiVA.org:liu-151317DiVA, id: diva2:1248833
Available from: 2018-09-17 Created: 2018-09-17 Last updated: 2024-08-22Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Aziz, Shazed
In the same journal
ACS Nano
Medical and Health SciencesMaterials Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 53 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf