liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Establishing the European diagnostic reference levels for interventional cardiology
STUK Radiat and Nucl Safety Author, Finland.
Univ Belgrade, Serbia.
Belgian Nucl Res Ctr SCK CEN, Belgium.
Univ Hosp Rijelca, Croatia.
Show others and affiliations
2018 (English)In: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 54, p. 42-48Article in journal (Refereed) Published
Abstract [en]

Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14,922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm(2)), percutaneous coronary intervention (PCI, 85 Gy cm(2)), transcatheter aortic valve implantation (TAVI, 130 Gy cm(2)), electrophysiological procedures (12 Gy cm(2)) and pacemaker implantations Pacemaker implantations were further divided into single-chamber (2.5 Gy cm(2)) and dual chamber (3.5 Gy cm(2)) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm(2)). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology.

Place, publisher, year, edition, pages
ELSEVIER SCI LTD , 2018. Vol. 54, p. 42-48
Keywords [en]
Diagnostic reference levels; Interventional cardiology
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-152392DOI: 10.1016/j.ejmp.2018.09.012ISI: 000447271300006PubMedID: 30337009OAI: oai:DiVA.org:liu-152392DiVA, id: diva2:1259627
Available from: 2018-10-30 Created: 2018-10-30 Last updated: 2019-05-01

Open Access in DiVA

fulltext(787 kB)628 downloads
File information
File name FULLTEXT02.pdfFile size 787 kBChecksum SHA-512
af8b6b7c0ef854b5ba65c219eeb0dad84781ae5c083026c5eb9b7f6c34bf65d60f14f3548c125faba059596ee99882af4e0b735e961e19a5a927b3dc71f67e0e
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Sandborg, Michael

Search in DiVA

By author/editor
Sandborg, Michael
By organisation
Division of Radiological SciencesFaculty of Medicine and Health SciencesCenter for Medical Image Science and Visualization (CMIV)Medical radiation physics
In the same journal
Physica medica (Testo stampato)
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 629 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 136 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf