Visually Supporting Multiple Needle Placement in Irreversible Electroporation Interventions
Visual Computing Group, Ulm University, Ulm, Germany.
Karolinska Institutet Stockholm, Stockholm, Sweden.
Visual Computing Group, Ulm University, Ulm, Germany.ORCID iD: 0000-0002-7857-5512
2018 (English)In: Computer Graphics Forum, Vol. 37, no 6, p. 59-71Article in journal (Refereed) Published
Abstract [en]

Irreversible electroporation (IRE) is a minimally invasive technique for small tumour ablation. Multiple needles are inserted around the planned treatment zone and, depending on the size, inside as well. An applied electric field triggers instant cell death around this zone. To ensure the correct application of IRE, certain criteria need to be fulfilled. The needles' placement in the tissue has to be parallel, at the same depth, and in a pattern which allows the electric field to effectively destroy the targeted lesions. As multiple needles need to synchronously fulfill these criteria, it is challenging for the surgeon to perform a successful IRE. Therefore, we propose a visualization which exploits intuitive visual coding to support the surgeon when conducting IREs. We consider two scenarios: first, to monitor IRE parameters while inserting needles during laparoscopic surgery; second, to validate IRE parameters in post‐placement scenarios using computed tomography. With the help of an easy to comprehend and lightweight visualization, surgeons are enabled to quickly visually detect what needs to be adjusted. We have evaluated our visualization together with surgeons to investigate the practical use for IRE liver ablations. A quantitative study shows the effectiveness compared to a single 3D view placement method.

Place, publisher, year, edition, pages
Wiley-Blackwell Publishing Inc., 2018. Vol. 37, no 6, p. 59-71
National Category
Other Medical Biotechnology
Identifiers
URN: urn:nbn:se:liu:diva-152563DOI: 10.1111/cgf.13311ISI: 000437272800004Scopus ID: 2-s2.0-85038627097OAI: oai:DiVA.org:liu-152563DiVA, id: diva2:1261284
Note

(EuroVis Fast Track Revision)

Available from: 2018-11-06 Created: 2018-11-06 Last updated: 2018-11-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Ropinski, Timo

Search in DiVA

By author/editor
Ropinski, Timo
Other Medical Biotechnology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 241 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf