Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems
Lund Univ, Sweden.
Linköping University, Department of Biomedical Engineering. Linköping University, Faculty of Science & Engineering. Elekta Instrument AB, Sweden.
Lund Univ, Sweden.
Skane Univ Hosp, Sweden.
Show others and affiliations
2019 (English)In: PLoS ONE, ISSN 1932-6203, E-ISSN 1932-6203, Vol. 14, no 3, article id e0214238Article in journal (Refereed) Published
Abstract [en]

Microstructure imaging techniques based on tensor-valued diffusion encoding have gained popularity within the MRI research community. Unlike conventional diffusion encoding-applied along a single direction in each shot-tensor-valued encoding employs diffusion encoding along multiple directions within a single preparation of the signal. The benefit is that such encoding may probe tissue features that are not accessible by conventional encoding. For example, diffusional variance decomposition (DIVIDE) takes advantage of tensor-valued encoding to probe microscopic diffusion anisotropy independent of orientation coherence. The drawback is that tensor-valued encoding generally requires gradient waveforms that are more demanding on hardware; it has therefore been used primarily in MRI systems with relatively high performance. The purpose of this work was to explore tensorvalued diffusion encoding on clinical MRI systems with varying performance to test its technical feasibility within the context of DIVIDE. We performed whole-brain imaging with linear and spherical b-tensor encoding at field strengths between 1.5 and 7 T, and at maximal gradient amplitudes between 45 and 80 mT/m. Asymmetric gradient waveforms were optimized numerically to yield b-values up to 2 ms/mu m(2). Technical feasibility was assessed in terms of the repeatability, SNR, and quality of DIVIDE parameter maps. Variable system performance resulted in echo times between 83 to 115 ms and total acquisition times of 6 to 9 minutes when using 80 signal samples and resolution 2x2x4 mm(3). As expected, the repeatability, signal-to-noise ratio and parameter map quality depended on hardware performance. We conclude that tensor-valued encoding is feasible for a wide range of MRI systems-even at 1.5 T with maximal gradient waveform amplitudes of 33 mT/m-and baseline experimental design and quality parameters for all included configurations. This demonstrates that tissue features, beyond those accessible by conventional diffusion encoding, can be explored on a wide range of MRI systems.

Place, publisher, year, edition, pages
PUBLIC LIBRARY SCIENCE , 2019. Vol. 14, no 3, article id e0214238
National Category
Signal Processing
Identifiers
URN: urn:nbn:se:liu:diva-156388DOI: 10.1371/journal.pone.0214238ISI: 000462594000045PubMedID: 30921381OAI: oai:DiVA.org:liu-156388DiVA, id: diva2:1305732
Note

Funding Agencies|Swedish Research Council [2016-03443]; Swedish Foundation for Strategic Research [AM13-0090]; Random Walk Imaging AB [MN15]

Available from: 2019-04-18 Created: 2019-04-18 Last updated: 2019-08-12

Open Access in DiVA

fulltext(3512 kB)87 downloads
File information
File name FULLTEXT01.pdfFile size 3512 kBChecksum SHA-512
bf359614e1110d06ef6b7ef7542ab9a01819e73d6713636b0b3ab32473622aba787c4037f72aa55fabcc12a61ccaa0735a3a6ca008eed9fd3188a9ff86ffcf7d
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Sjölund, Jens
By organisation
Department of Biomedical EngineeringFaculty of Science & Engineering
In the same journal
PLoS ONE
Signal Processing

Search outside of DiVA

GoogleGoogle Scholar
Total: 87 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 87 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf