Correlation-Based Calibration for Nonlinearity Mismatches in Dual-Channel TIADCs
Natl Univ Def Technol, Peoples R China.
Natl Univ Def Technol, Peoples R China.
Linköping University, Department of Electrical Engineering, Communication Systems. Linköping University, Faculty of Science & Engineering.
Natl Univ Def Technol, Peoples R China.
Show others and affiliations
2020 (English)In: IEEE Transactions on Circuits and Systems - II - Express Briefs, ISSN 1549-7747, E-ISSN 1558-3791, Vol. 67, no 3, p. 585-589Article in journal (Refereed) Published
Abstract [en]

Mismatches affect the dynamic performance of time-interleaved analog-to-digital converters (TIADCs). Linear mismatches can be calibrated by many mature methods, but if higher performance is required, nonlinearity mismatches have to be suppressed. The background calibration method based on input-free band (IFB) functions poorly for narrow-band signals. This brief proposes a correlation-based calibration method for nonlinearity mismatches in dual-channel TIADCs which behaves well for both wide-band and narrow-band signals. The output samples are calibrated by reducing the residual distortions which are approximated by multiplying the pseudo distortions and the estimated mismatch coefficients. The pseudo distortions are acquired by using a frequency-shifter, a differentiator, and multipliers. The coefficients which indicate the mismatch strength are estimated by eliminating the cross-correlation of the calibrated output samples and the calibrated pseudo distortions at zero lag. Simulations show that the proposed method can improve the SFDR by dozens of dBc for narrow-band input signals, compared with the IFB method. For the 16-QAM signal, the error vector magnitude improvement over the IFB method is 35.48 dB.

Place, publisher, year, edition, pages
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC , 2020. Vol. 67, no 3, p. 585-589
Keywords [en]
Estimation; Calibration; Nonlinear distortion; Integrated circuit modeling; Buffer storage; Time-interleaved (TI); analog-to-digital converter (ADC); nonlinearity mismatches; calibration; correlation; background estimation
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:liu:diva-165483DOI: 10.1109/TCSII.2019.2916430ISI: 000526541600036OAI: oai:DiVA.org:liu-165483DiVA, id: diva2:1428583
Note

Funding Agencies|National Natural Science Foundation of ChinaNational Natural Science Foundation of China [61701509, 61704191]

Available from: 2020-05-06 Created: 2020-05-06 Last updated: 2020-05-06

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Search in DiVA

By author/editor
Johansson, Håkan
By organisation
Communication SystemsFaculty of Science & Engineering
In the same journal
IEEE Transactions on Circuits and Systems - II - Express Briefs
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 290 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf