liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Standardized Measurement of Capillary Refill Time using Novel Technology
Linköping University, Department of Clinical and Experimental Medicine, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Disaster Medicine and Traumatology.ORCID iD: 0000-0003-3708-1978
Linköping University, Department of Clinical and Experimental Medicine, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Disaster Medicine and Traumatology.ORCID iD: 0000-0003-1383-375X
Linköping University, Department of Medical and Health Sciences, Division of Drug Research. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Local Health Care Services in Central Östergötland, Department of Emergency Medicine in Linköping.
2019 (English)In: Prehospital and Disaster Medicine, ISSN 1049-023X, E-ISSN 1945-1938, Vol. 34, no s1, p. 167-168Article in journal, Meeting abstract (Other academic) Published
Abstract [en]

Introduction: In a patient going into shock, blood is redistributed from the periphery to the central circulation, making an assessment of skin perfusion useful in a prehospital setting. Capillary refill time (CRT) is the time required for a pressure blanched skin site to reperfuse. Currently, CRT is tested by manually applying pressure for 5s to the skin and observing the time before reperfusion. Guidelines state that CRT should be 2-3s in a healthy patient. Shortcomings in this procedure include lack of standardization of pressure, subjective assessment of the time for reperfusion, and not accounting for the patient’s skin temperature.

Aim: To develop a standardized objective procedure for testing CRT in the prehospital setting.

Method: The study protocol was approved by the Ethics Committee at Linköping University (M200-07, 2015-99-31). An electro-pneumatic device exerting constant force (9N) over 5s was developed. CRT was measured using the Tissue Viability Imager (Wheelsbridge AB, Sweden) which relies on polarization spectroscopy. To simulate hypothermic conditions, healthy volunteers were subjected to low ambient temperature (8°C). Blood loss was simulated using a custom-built lower body negative pressure (LBNP) chamber. In both scenarios, the CRT test was carried out on three test sites (finger pulp, forehead, and sternum).

Results: CRT on the finger pulp and sternum was shown to be increased following the hypothermic conditions, but not on the forehead. Skin temperature on the three sites followed the same pattern, with the forehead being virtually unchanged. Tests performed during LBNP revealed an apparent effect on CRT following the simulated blood loss, with prolonged CRT for all sites tested.

Discussion: A successful methodology for objective assessment of CRT was developed, which was validated on healthy volunteers following hypothermia or simulated blood loss. Ongoing work will investigate a combination of hypothermia and blood loss to more accurately simulate the prehospital setting.

Place, publisher, year, edition, pages
Cambridge University Press , 2019. Vol. 34, no s1, p. 167-168
National Category
Physiology
Identifiers
URN: urn:nbn:se:liu:diva-169365DOI: 10.1017/S1049023X19003820OAI: oai:DiVA.org:liu-169365DiVA, id: diva2:1467222
Conference
21st WADEM congress on disaster and emergency medicine, Brisbane, Australia, May 7-10, 2019
Available from: 2020-09-15 Created: 2020-09-15 Last updated: 2021-12-29

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Junker, JohanJonson, Carl-OscarHenricson, Joakim

Search in DiVA

By author/editor
Junker, JohanJonson, Carl-OscarHenricson, Joakim
By organisation
Division of Surgery, Orthopedics and OncologyFaculty of Medicine and Health SciencesCenter for Disaster Medicine and TraumatologyDivision of Drug ResearchDepartment of Emergency Medicine in Linköping
In the same journal
Prehospital and Disaster Medicine
Physiology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 123 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf