liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Prehospital Monitoring of Vital Parameters Using a Novel Device - RespiHeart
Linköping University, Department of Clinical and Experimental Medicine, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Disaster Medicine and Traumatology.ORCID iD: 0000-0003-3708-1978
Linköping University, Department of Clinical and Experimental Medicine, Division of Surgery, Orthopedics and Oncology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Disaster Medicine and Traumatology.ORCID iD: 0000-0003-1383-375x
2017 (English)In: Prehospital and Disaster Medicine, ISSN 1049-023X, E-ISSN 1945-1938, Vol. 32, no Suppl. 1, p. S165-S166Article in journal, Meeting abstract (Refereed) Published
Abstract [en]

Study/Objective: The study aims at validating a novel device (RespiHeart) for monitoring vital parameters in traumatically injured patients. Background: There is a need for a simple-to-use method for monitoring of vital parameters in the prehospital setting. RespiHeart is a small medical device that is attached to the sternum. It sends light of defined wavelengths into the underlying vasculature, and measures the reflected light. The resulting signals are then treated using proprietary algorithms to obtain heart rate and respiratory rate. The device has the capability to also measure oxygen saturation, temperature and movement. Methods: The device was tested during training sessions for medical personnel, where various traumatic wounds were inflicted on anesthetized pigs. The training was primarily focused on teaching acute lifesaving interventions. The RespiHeart device was applied to the animal and used to monitor vital parameters throughout the training session. A total of 22 animals were included in the study. The data gathered from Respiheart were compared to results from a pulse oximeter and ventilator connected to the animal. Statistical comparison were performed using linear regression and Bland-Altman plots to analyze agreement of methods. Results: The heart rate as measured by the pulse oximeter was correlated to the rate reported by RespiHeart. The R2 was 0.9946 with a p-value of less than 0.0001. Bland-Altman analysis of heart rate revealed a bias of -0.06127 (95% CI -2.219- 2.097). The respiratory rate as set on the ventilator was correlated to the rate reported by RespiHeart. The R2 was 0.9978 with a p-value of less than 0.0001. Bland-Altman analysis of respiratory rate revealed a bias of -0.008584 (95% CI -0.42-0.4028). Conclusion: The results obtained in this study demonstrate a high degree of correlation between the data obtained from RespiHeart and the pulse oximeter and ventilator. This renders RespiHeart as a promising device for prehospital use.

Place, publisher, year, edition, pages
Cambridge University Press, 2017. Vol. 32, no Suppl. 1, p. S165-S166
National Category
Anesthesiology and Intensive Care Medical Instrumentation
Identifiers
URN: urn:nbn:se:liu:diva-169698DOI: 10.1017/S1049023X17004460OAI: oai:DiVA.org:liu-169698DiVA, id: diva2:1468053
Conference
WADEM Congress on Disaster and Emergency Medicine 2017
Available from: 2020-09-16 Created: 2020-09-16 Last updated: 2025-02-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Junker, JohanJonson, Carl-Oscar

Search in DiVA

By author/editor
Junker, JohanJonson, Carl-Oscar
By organisation
Division of Surgery, Orthopedics and OncologyFaculty of Medicine and Health SciencesCenter for Disaster Medicine and Traumatology
In the same journal
Prehospital and Disaster Medicine
Anesthesiology and Intensive CareMedical Instrumentation

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 156 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf