liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A Novel Approach to Hematology Testing at the Point of Care
PixCell Med Technol Ltd, Israel.
Uppsala Univ, Sweden.
Linköping University, Department of Biomedical and Clinical Sciences, Division of Clinical Chemistry and Pharmacology. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Department of Clinical Chemistry.
PixCell Med Technol Ltd, Israel.
Show others and affiliations
2021 (English)In: JOURNAL OF APPLIED LABORATORY MEDICINE, ISSN 2576-9456, Vol. 6, no 2, p. 532-542Article in journal (Refereed) Published
Abstract [en]

Background: The need for rapid point-of-care (POC) diagnostics is now becoming more evident due to the increasing need for timely results and improvement in healthcare service. With the recent COVID-19 pandemic outbreak, POC has become critical in managing the spread of disease. Applicable diagnostics should be readily deployable, easy to use, portable, and accurate so that they fit mobile laboratories, pop-up treatment centers, field hospitals, secluded wards within hospitals, or remote regions, and can be operated by staff with minimal training. Complete blood count (CBC), however, has not been available at the POC in a simple-to-use device until recently. The HemoScreen, which was recently cleared by the FDA for POC use, is a miniature, easy-to-use instrument that uses disposable cartridges and may fill this gap. Content: The HemoScreens analysis method, in contrast to standard laboratory analyzers, is based on machine vision (image-based analysis) and artificial intelligence (AI). We discuss the different methods currently used and compare their results to the vision-based one. The HemoScreen is found to correlate well to laser and impedance-based methods while emphasis is given to mean cell volume (MCV), mean cell hemoglobin (MCH), and platelets (PLT) that demonstrate better correlation when the vision-based method is compared to itself due to the essential differences between the underlying technologies. Summary: The HemoScreen analyzer demonstrates lab equivalent performance, tested at different clinical settings and sample characteristics, and might outperform standard techniques in the presence of certain interferences. This new approach to hematology testing has great potential to improve quality of care in a variety of settings.

Place, publisher, year, edition, pages
OXFORD UNIV PRESS INC , 2021. Vol. 6, no 2, p. 532-542
National Category
Medical Laboratory and Measurements Technologies
Identifiers
URN: urn:nbn:se:liu:diva-174649DOI: 10.1093/jalm/jfaa186ISI: 000625293300023PubMedID: 33274357OAI: oai:DiVA.org:liu-174649DiVA, id: diva2:1541545
Available from: 2021-04-01 Created: 2021-04-01 Last updated: 2021-04-01

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Aardal, Elisabeth
By organisation
Division of Clinical Chemistry and PharmacologyFaculty of Medicine and Health SciencesDepartment of Clinical Chemistry
Medical Laboratory and Measurements Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 162 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf