liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
On the Consequences of Poorly Defined Breakpoints for Rifampin Susceptibility Testing of Mycobacterium tuberculosis Complex
Univ Cambridge, England.
FIND, Switzerland.
Linköping University, Department of Biomedical and Clinical Sciences, Division of Inflammation and Infection. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Medicine Center, Department of Infectious Diseases. Department of Infectious Diseases, Kalmar County Hospital,Sweden.
Univ S Florida, FL 33620 USA; Univ S Florida, FL 33620 USA.
2021 (English)In: Journal of Clinical Microbiology, ISSN 0095-1137, E-ISSN 1098-660X, Vol. 59, no 4, article id e02328-20Article in journal, Editorial material (Other academic) Published
Abstract [en]

In a recent report of a systematic review of critical concentrations (CCs), the World Health Organization (WHO) lowered the rifampin (RIF) CC for antimicrobial susceptibility testing (AST) of the Mycobacterium tuberculosis complex using Middlebrook 7H10 medium and the Bactec Mycobacterial Growth Indicator Tube (MGIT) 960 system from 1 to 0.5mg/ ml. The previous RIF CC for 7H10 had been in use for over half a century. Because it had served as the de facto reference standard, it contributed to the endorsement of inappropriately high CCs for other AST methods, including the U.S. Food and Drug Administration (FDA)-approved MGIT system. Moreover, this resulted in confusion about the interpretation of seven borderline resistance mutations in rpoB (i.e., L430P, D435Y, H445L, H445N, H445S, L452P, and I491F). In this issue of the Journal of Clinical Microbiology, Shea et al. (J Clin Microbiol 59:e01885-20, 2021, https://doi.org/10.1128/JCM.01885-20) provide evidence that the CC endorsed by the Clinical and Laboratory Standards Institute for the Sensititre MYCOTB system, which is not FDA approved but is CE-IVD marked in the European Union, is likely also too high. These findings underscore the importance of calibrating AST methods against a rigorously defined reference standard, as recently proposed by the European Committee on Antimicrobial Susceptibility Testing, as well as the value of routine next-generation sequencing for investigating discordant AST results.

Place, publisher, year, edition, pages
AMER SOC MICROBIOLOGY , 2021. Vol. 59, no 4, article id e02328-20
National Category
Infectious Medicine
Identifiers
URN: urn:nbn:se:liu:diva-175071DOI: 10.1128/JCM.02328-20ISI: 000631260500014PubMedID: 33568463OAI: oai:DiVA.org:liu-175071DiVA, id: diva2:1545619
Available from: 2021-04-20 Created: 2021-04-20 Last updated: 2022-04-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Schön, Thomas
By organisation
Division of Inflammation and InfectionFaculty of Medicine and Health SciencesDepartment of Infectious Diseases
In the same journal
Journal of Clinical Microbiology
Infectious Medicine

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 116 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf