liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Cutaneous bioengineering instrumentation standardization: the Tissue Viability Imager
Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation. Linköping University, The Institute of Technology.
University of California.
University of California.
Show others and affiliations
2009 (English)In: Skin research and technology, ISSN 0909-752X, Vol. 15, no 1, 6-13 p.Article in journal (Refereed) Published
Abstract [en]

Tissue Viability Imaging (TiVi) is a new bioengineering technology intended for remote two-dimensional mapping of skin red blood cell concentration (RBCconc). Before use in the laboratory, work-site and dermatology clinic, critical performance parameters of this emerging technology require careful evaluation.

To assess short- and long-term stability, image uniformity, distance and image size dependence, ambient light and curvature influence in a production batch of Tissue Viability Imagers.

Four Tissue Viability Imagers from the same production batch were evaluated at two laboratories (one industrial and one dermatological) with respect to critical parameter performance.

The average systematic drift in sensitivity over time was 0.27% and < 1.02% for all four units tested. Difference in sensitivity between units was limited to 4.1% and was due to offset rather than gain deviation. Spatial variation in image uniformity was below 3.08% and 1.93% in the corners and centre of an individual image, respectively. This spatial variation could be further reduced to 0.25% and 0.13%, respectively by image normalization. Ambient light from a 40 W bulb or a 11 W fluorescent light source at a distance of 50-60 cm above the object, reduced the recorded values by about 10%, while the camera to object distance and image size had no detectable influence on sensitivity. Curved objects, such as human forearm, demonstrated an edge effect limited to below 10%.

The critical TiVi performance parameters evaluated proved stable in relation to expected variations in skin RBCconc over time. Calibration by way of a two-point method may reduce differences in sensitivity between instruments to further facilitate inter-laboratory comparison of results.

Place, publisher, year, edition, pages
2009. Vol. 15, no 1, 6-13 p.
Keyword [en]
Tissue Viability Imaging, skin red blood cell concentration, spectroscopy, instrument performance, skin bioengineering
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-16611DOI: 10.1111/j.1600-0846.2008.00330.xOAI: oai:DiVA.org:liu-16611DiVA: diva2:159517
Available from: 2009-02-07 Created: 2009-02-06 Last updated: 2009-05-08

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Nilsson, Gert

Search in DiVA

By author/editor
Nilsson, Gert
By organisation
Biomedical InstrumentationThe Institute of Technology
In the same journal
Skin research and technology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 521 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf