liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Output performance of the novel active transcutaneous bone conduction implant Sentio at different stimulation sites
Hannover Med Sch, Germany; Hannover Med Sch, Germany; Stadtfelddamm 34, Germany.
Linköping University, Department of Biomedical and Clinical Sciences, Division of Sensory Organs and Communication. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0003-3350-8997
Oticon Med, Denmark.
Hannover Med Sch, Germany; Hannover Med Sch, Germany; Cluster Excellence Hearing4all, Germany.
Show others and affiliations
2022 (English)In: Hearing Research, ISSN 0378-5955, E-ISSN 1878-5891, Vol. 421, article id 108369Article in journal (Refereed) Published
Abstract [en]

Objectives: The output performance of a novel semi-implantable transcutaneous bone conduction device was compared to an established percutaneous bone-anchored hearing system device using cadaver heads. The influence of actuator position, tissue growth below the actuator and mounting it on the surface or in a flattened bone bed on the performance of the implanted actuator was investigated.Materials and Methods: The percutaneous and the new transcutaneous device were sequentially implanted at two sites in five human cadaver heads: 55 mm superior-posterior to the ear canal opening (position A) and, closer to the cochlea, about 20 mm inferior-posterior to the ear canal opening behind the pinna on the mastoid (position B). The ipsi-and contralateral cochlear promontory (CP) velocity magnitude responses to percutaneous and transcutaneous stimulation were measured using laser Doppler vibrometry. In addition, the CP vibration of the transcutaneous device placed directly on the skull bone surface was compared with the placement in a flattened bone bed at a depth of about 3 mm. Finally, the influence of placing a thin silicone interposition layer under the implanted transducer was also explored.Results: The percutaneous device provided about an 11 dB higher average CP vibration level than the transcutaneous device at frequencies between 0.5 and 10 kHz. The ipsilateral CP vibration responses with stimulations at position B were on average 13 dB higher compared to stimulation at position A. The placement of the transcutaneous transducer at position B provided similar or higher average vibration magnitudes than the percutaneous transducer at position A. The 3 mm deep flattened bone bed had no significant effects on the output performance. Placing a thin silicone layer under the transcutaneous transducer had no significant influence on the output of the transcutaneous device.Conclusions: Our results using the CP vibration responses show that at frequencies above 500 Hz the new transcutaneous device at position B provides similar output levels as the percutaneous device at position A. The results also indicated that neither a bone bed for the placement of the transcutaneous transducer nor a simulated tissue growth between the actuator and the bone affect the output performance of the device.

Place, publisher, year, edition, pages
ELSEVIER , 2022. Vol. 421, article id 108369
Keywords [en]
Transcutaneous bone conduction implant; Bone anchored hearing device; Bone conduction
National Category
Otorhinolaryngology
Identifiers
URN: urn:nbn:se:liu:diva-186480DOI: 10.1016/j.heares.2021.108369ISI: 000812157500006PubMedID: 34728110OAI: oai:DiVA.org:liu-186480DiVA, id: diva2:1677532
Note

Funding Agencies|DFG Cluster of Excellence [EXC 1077/1]; Oticon Medical and William Demant Foundation

Licensing: CC BY license ( http://creativecommons.org/licenses/by/4.0/ )

Available from: 2022-06-28 Created: 2022-06-28 Last updated: 2022-06-28

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Stenfelt, Stefan
By organisation
Division of Sensory Organs and CommunicationFaculty of Medicine and Health Sciences
In the same journal
Hearing Research
Otorhinolaryngology

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 45 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf