Compensating for Respiratory Artifacts in Blood Pressure Waveforms
Linköping University, Department of Electrical Engineering.
2004 (English)Independent thesis Basic level (professional degree)Student thesisAlternative title
Hemodynamisk kompensering för andningsartefakter (Swedish)
Abstract [en]

Cardiac catheterization has for a long time been a valuable way to evaluate the hemodynamics of a patient. One of the benefits is that the entire blood pressure waveform can be recorded and visualized to the cardiologist. These measurements are however disturbed by different phenomenon, such as respiration and the dynamics of the fluid filled catheter, which introduces artifacts in the blood pressure waveform. If these disturbances could be removed, the measurement would be more accurate. This report focuses on the effects of respiratory artifacts in blood pressure signals during cardiac catheterization.

Four methods, a standard bandpass filter, two adaptive filters and one wavelet based method are considered. The difference between respiratory artifacts in systolic and diastolic pressure is studied and dealt with during compensation. All investigated methods are implemented in Matlab and validated against blood pressure signals from catheterized patients.

The results are algorithms that try to correct for respiratory artifacts. The rate of success is hard to determine since only a few measured blood pressure signals have been available and since the size and appearance of the actual artifacts are unknown.

Place, publisher, year, edition, pages
Institutionen för systemteknik , 2004. , 52 p.
Series
LiTH-ISY-Ex, 2004:3654
Keyword [en]
Reglerteknik, Cardiac catheterization, respiratory artifacts, artifact removal
Keyword [sv]
Reglerteknik
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:liu:diva-2942OAI: oai:DiVA.org:liu-2942DiVA: diva2:20285
Uppsok
teknik
Available from: 2005-06-16 Created: 2005-06-16

Open Access in DiVA

fulltext(934 kB)1544 downloads
File information
File name FULLTEXT01.pdfFile size 934 kBChecksum SHA-1
7e365db455460fa9ccfc93bcd3ecf1a40435ad5b3eb6e8692b072bc0d514d7c945fc3f43
Type fulltextMimetype application/pdf

By organisation
Department of Electrical Engineering
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1544 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 257 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf