Standardized Volume Rendering Protocols for Magnetic Resonance Imaging using Maximum-Likelihood Modeling
Linköping University, Department of Science and Technology.
2006 (English)Independent thesis Advanced level (degree of Magister), 20 points / 30 hpStudent thesis
Abstract [en]

Volume rendering (VRT) has been used with great success in studies of patients using computed tomography (CT), much because of the possibility of standardizing the rendering protocols. When using magnetic resonance imaging (MRI), this procedure is considerably more difficult, since the signal from a given tissue can vary dramatically, even for the same patient. This thesis work focuses on how to improve the presentation of MRI data by using VRT protocols including standardized transfer functions. The study is limited to exclusively examining data from patients with suspected renal artery stenosis. A total number of 11 patients are examined.

A statistical approach is used to standardize the volume rendering protocols. The histogram of the image volume is modeled as the sum of two gamma distributions, corresponding to vessel and background voxels. Parameters describing the gamma distributions are estimated with a Maximum-likelihood technique, so that expectation (E1 and E2) and standard deviation of the two voxel distributions can be calculated from the histogram. These values are used to generate the transfer function.

Different combinations of the values from the expectation and standard deviation were studied in a material of 11 MR angiography datasets, and the visual result was graded by a radiologist. By comparing the grades, it turned out that using only the expectation of the background distribution (E1) and vessel distribution (E2) gave the best result. The opacity is then defined with a value of 0 up to a signal threshold of E1, then increasing linearly up to 50 % at a second threshold E2, and after that a constant opacity of 50 %. The brightness curve follows the opacity curve to E2, after which it continues to increase linearly up to 100%.

A graphical user interface was created to facilitate the user-control of the volumes and transfer functions. The result from the statistical calculations is displayed in the interface and is used to view and manipulate the transfer function directly in the volume histogram.

A transfer function generated with the Maximum-likelihood VRT method (ML-VRT) gave a better visual result in 10 of the 11 cases than when using a transfer function not adapting to signal intensity variations.

Place, publisher, year, edition, pages
Institutionen för teknik och naturvetenskap , 2006. , 48 p.
Keyword [en]
Volume Rendering, MRI, Transfer function, ML-VRT, Standardized
National Category
Computer Vision and Robotics (Autonomous Systems)
Identifiers
URN: urn:nbn:se:liu:diva-6211ISRN: LITH-ITN-MT-EX--06/008--SEOAI: oai:DiVA.org:liu-6211DiVA: diva2:21703
Presentation
2006-01-27, CMIV, Linköpings universitet/US, SE-581 85, Linköping, 13:00
Uppsok
teknik
Supervisors
Examiners
Available from: 2006-04-04 Created: 2006-04-04

Open Access in DiVA

fulltext(1607 kB)754 downloads
File information
File name FULLTEXT01.pdfFile size 1607 kBChecksum MD5
3c2f86263b274cbd33974e07f25dfaa689f8a7bc8c0cc6221a9875d9866a43764bbad6af
Type fulltextMimetype application/pdf

By organisation
Department of Science and Technology
Computer Vision and Robotics (Autonomous Systems)

Search outside of DiVA

GoogleGoogle Scholar
Total: 754 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1348 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf