Abstract [en]

Tendon healing is a slow process and the tendon may not regain its initial mechanical properties after rupture. Mechanical stimuli have shown to have positive effect on tendon healing. This study is the first to investigate the effect of vibration stimuli on healing tendons. Vibration was also compared to treadmill running, which has previously been used for mechanical stimuli.63 female Sprauge-Dawley rats were used. A 3 mm segment was removed from the Achilles tendon and the tendon was left to heal. The animals were subjected to 15 min of daily exercise, vibration or treadmill running or acted as controls without exercise. The study was divided into three experiments. Experiment 1; the animals had full time cage activity and was randomized into running, vibration and control group. Experiment 2; the animals were unloaded and randomized into vibration, running and control group. There was also a control group with full time cage activity in experiment 2. Experiment 3; the animals were unloaded and randomized into vibration and placebo group. 14 days after surgery the animals were killed and mechanical testing of the Achilles tendons was performed. The results showed no significant difference between the groups in experiment 1. Experiment 2 showed that controls with full time cage activity had higher peak load, stiffness and cross sectional area than unloaded running, vibration and control groups. In experiment 3, there was no significant difference between vibration and placebo group. In conclusion, this study shows that vibration, as applied here, does not affect tendon healing.

Place, publisher, year, edition, pages
2009. , 46 p.
Keyword [en]
Mechanical Stimuli, Vibration, Tendon Healing
National Category
URN: urn:nbn:se:liu:diva-19329ISRN: LITH-IFM-A-EX--09/2201--SEOAI: diva2:224407
2009-06-10, Planck, Linköping, 09:00 (Swedish)
Available from: 2009-06-23 Created: 2009-06-17 Last updated: 2009-06-23Bibliographically approved

Open Access in DiVA

The Effect of Mechanical Stimuli on Healing Achilles Tendons in Rats(3812 kB)610 downloads
File information
File name FULLTEXT01.pdfFile size 3812 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Malis, Emma
By organisation
Department of Physics, Chemistry and Biology

Search outside of DiVA

GoogleGoogle Scholar
Total: 610 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 203 hits
ReferencesLink to record
Permanent link

Direct link