Iterative Filtered Backprojection Methods for Helical Cone-Beam CT
Linköping University, Department of Electrical Engineering, Computer Vision . Linköping University, The Institute of Technology.
2009 (English)Doctoral thesis, monograph (Other academic)
Abstract [en]

State-of-the-art reconstruction algorithms for medical helical cone-beam Computed Tomography (CT) are of type non-exact Filtered Backprojection (FBP). They are attractive because of their simplicity and low computational cost, but they produce sub-optimal images with respect to artifacts, resolution, and noise. This thesis deals with possibilities to improve the image quality by means of iterative techniques.

The first algorithm, Regularized Iterative Weighted Filtered Backprojection (RIWFBP), is an iterative algorithm employing the non-exact Weighted FilteredBackprojection (WFBP) algorithm [Stierstorfer et al., Phys. Med. Biol. 49, 2209-2218, 2004] in the update step. We have measured and compared artifact reduction as well as resolution and noise properties for RIWFBP and WFBP. The results show that artifacts originating in the non-exactness of the WFBP algorithm are suppressed within five iterations without notable degradation in terms of resolution versus noise. Our experiments also indicate that the number of required iterations can be reduced by employing a technique known as ordered subsets.

A small modification of RIWFBP leads to a new algorithm, the Weighted Least Squares Iterative Filtered Backprojection (WLS-IFBP). This algorithm has a slightly lower rate of convergence than RIWFBP, but in return it has the attractive property of converging to a solution of a certain least squares minimization problem. Hereby, theory and algorithms from optimization theory become applicable.

Besides linear regularization, we have examined edge-preserving non-linear regularization.In this case, resolution becomes contrast dependent, a fact that can be utilized for improving high contrast resolution without degrading the signal-to-noise ratio in low contrast regions. Resolution measurements at different contrast levels and anthropomorphic phantom studies confirm this property. Furthermore, an even morepronounced suppression of artifacts is observed.

Iterative reconstruction opens for more realistic modeling of the input data acquisition process than what is possible with FBP. We have examined the possibility to improve the forward projection model by (i) multiple ray models, and (ii) calculating strip integrals instead of line integrals. In both cases, for linearregularization, the experiments indicate a trade off: the resolution is improved atthe price of increased noise levels. With non-linear regularization on the other hand, the degraded signal-to-noise ratio in low contrast regions can be avoided.

Huge input data sizes make experiments on real medical CT data very demanding. To alleviate this problem, we have implemented the most time consuming parts of the algorithms on a Graphics Processing Unit (GPU). These implementations are described in some detail, and some specific problems regarding parallelism and memory access are discussed.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press , 2009. , 168 p.
Series
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 1264
Keyword [en]
Iterative reconstruction, filtered backprojection, regularization, cone-beam CT
National Category
Medical Laboratory and Measurements Technologies
Identifiers
URN: urn:nbn:se:liu:diva-20035ISBN: 978-91-7393-586-9 (print)OAI: oai:DiVA.org:liu-20035DiVA: diva2:232734
Public defence
2009-09-25, Glashuset, Hus B,, Campus Valla, Linköping University, Linköping, 09:15 (English)
Opponent
Supervisors
Available from: 2009-08-31 Created: 2009-08-25 Last updated: 2016-05-04Bibliographically approved

Open Access in DiVA

Iterative Filtered Backprojection Methods for Helical Cone-Beam CT(4190 kB)8125 downloads
File information
File name FULLTEXT01.pdfFile size 4190 kBChecksum SHA-512
6e61a3676f6d573480b1244d921400049c9c07d8a9c07cad48bacb3cd03952d193fbf44b28af22246587b46ee7a5fd9c3a7f6e4792b6a940e07b3f09979f1412
Type fulltextMimetype application/pdf
Cover(98 kB)58 downloads
File information
File name COVER01.pdfFile size 98 kBChecksum SHA-512
d0fc19219dfd41d22004ab9f0a31fcdc6bf2b17c464ee91b32bf4f9239613421b9adb6d82d749dcd4281e54bab2b6eb053afce4360056dcc587e97049199fd9f
Type coverMimetype application/pdf

Authority records BETA

Sunnegårdh, Johan

Search in DiVA

By author/editor
Sunnegårdh, Johan
By organisation
Computer Vision The Institute of Technology
Medical Laboratory and Measurements Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 8125 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 4853 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf