Calculating effective dose on a cone beam computed tomographydevice: 3D Accuitomo and 3D Accuitomo FPD
Public Dental Health, Göteborg.
Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Göteborg, Sweden.
Department of Oral and Maxillofacial Radiology The Sahlgrenska Academy at Göteborg University, Sweden.
Linköping University, Department of Medicine and Health Sciences, Radiation Physics . Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Centre of Surgery and Oncology, Department of Radiation Physics.
Show others and affiliations
2008 (English)In: Dento-Maxillo-Facial Radiology, ISSN 0250-832X, Vol. 37, no 2, 72-79 p.Article in journal (Refereed) Published
Abstract [en]

Objectives: This study evaluates two methods for calculating effective dose, CT dose index (CTDI) and dose–area product (DAP) for a cone beam CT (CBCT) device: 3D Accuitomo at field size 30x40 mm and 3D Accuitomo FPD at field sizes 40x40 mm and 60x60 mm. Furthermore, the effective dose of three commonly used examinations in dental radiology was determined.

Methods: CTDI100 measurements were performed in a CT head dose phantom with a pencil ionization chamber connected to an electrometer. The rotation centre was placed in the centre of the phantom and also, to simulate a patient examination, in the upper left cuspid region. The DAP value was determined with a plane-parallel transmission ionization chamber connected to an electrometer. A conversion factor of 0.08 mSv per Gy cm2 was used to determine the effective dose from DAP values. Based on data from 90 patient examinations, DAP and effective dose were determined.

Results: CTDI100 measurements showed an asymmetric dose distribution in the phantom when simulating a patient examination. Hence a correct value of CTDIw could not be calculated. The DAP value increased with higher tube current and tube voltage values. The DAP value was also proportional to the field size. The effective dose was found to be 11–77 microSv for the specific examinations.

Conclusions: DAP measurement was found to be the best method for determining effective dose for the Accuitomo. Determination of specific conversion factors in dental radiology must, however, be further developed

Place, publisher, year, edition, pages
2008. Vol. 37, no 2, 72-79 p.
Keyword [en]
radiation dosimetry; limited cone beam computed tomography
National Category
Radiology, Nuclear Medicine and Medical Imaging
URN: urn:nbn:se:liu:diva-21450DOI: 10.1259/dmfr/60375385OAI: diva2:241368
Available from: 2009-10-02 Created: 2009-10-02 Last updated: 2011-01-11

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Helmrot, Ebba
By organisation
Radiation Physics Faculty of Health SciencesDepartment of Radiation Physics
In the same journal
Dento-Maxillo-Facial Radiology
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 43 hits
ReferencesLink to record
Permanent link

Direct link