Dose and image quality in the comparison of analogue and digital techniques in paediatric urology examinations.
Linköping University, Department of Medicine and Care, Radio Physics. Linköping University, Faculty of Health Sciences. Östergötlands Läns Landsting, Centre of Surgery and Oncology, Department of Radiation Physics.
Ryhov Hospital.
Ryhov Hospital.
Linköping University, Department of Medicine and Care, Radiation Physics. Linköping University, Faculty of Health Sciences.
2004 (English)In: European Radiology, ISSN 0938-7994, Vol. 14, no 4, 638-644 p.Article in journal (Refereed) Published
Abstract [en]

In paediatric radiology it has been recognised that children have a higher risk of developing cancer from the irradiation than adults (two to three times); therefore, increased attention has been directed towards the dose to the patient. In this study the effect on patient dose and image quality in replacing the exposure in micturating cystourethrography (MCUG) examinations with the stored fluoroscopy image has been investigated. In the intravenous urography (IVU) examination we compared analogue and digital image quality, but the dose measurements were performed on a phantom. Standard clinical X-ray equipment was used. Sixty-eight patients in each of two centres were studied for the MCUG. Doses were measured with a dose-area product (DAP) meter and the image quality was scored. A non-parametric statistical analysis was performed. For the IVU, a phantom was used in the dose measurements but clinical images were scored in the comparison between analogue and digital images. For the MCUG, replacing the exposure with stored fluoroscopy images lowered the DAP value from 0.77 to 0.50 Gy cm2. The image quality did not show any difference between the techniques; however, if reflux was to be graded, exposure was needed. For the IVU, the doses could be lowered by a factor of 3 using digital techniques. The image quality showed no statistical difference between the two techniques. There is a potential for a substantial dose reduction in both MUCG and IVU examinations using digital techniques.

Place, publisher, year, edition, pages
2004. Vol. 14, no 4, 638-644 p.
Keyword [en]
Radiation dose - Image quality - Paediatric radiology - Urology
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-21487DOI: 10.1007/s00330-003-2144-9OAI: diva2:241433
Available from: 2009-10-02 Created: 2009-10-02 Last updated: 2009-10-03

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Persliden, Jan
By organisation
Radio PhysicsFaculty of Health SciencesDepartment of Radiation PhysicsRadiation Physics
In the same journal
European Radiology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 15 hits
ReferencesLink to record
Permanent link

Direct link