Effects of contrast equalization on energy imparted to the patient: a comparison of two dental generators and two types of intraoral film.
Linköping University, Department of Medicine and Care, Radio Physics. (Landstinget i Östergötland)
n/a.
n/a.
1994 (English)In: Dento-Maxillo-Facial Radiology, ISSN 0250-832X, Vol. 23, no 2, 83-90 p.Article in journal (Refereed) Published
Abstract [en]

Technical evolution in maxillofacial radiology has in the last decade provided faster films and the constant potential generator. The consequences of these innovations for radiographic contrast and energy imparted to the patient are analysed. On the basis of physical measurements a test model has been developed for correcting exposure parameters in order to maintain or restore image contrast. These measurements are expressed in and developed from basic radiological concepts and physical formulas presented in an earlier paper (Helmrot E. et al., Dentomaxillofac. Radiol. 1991; 20: 135-46). The test model can also be used to demonstrate the balance between contrast and energy imparted to the patient in the radiographic process. Changing to constant potential generators and faster film may each result in a degradation in contrast, which is possible to restore by a controlled adjustment of the kV-setting. Maintenance of constant image quality results in a slight reduction in the net gain in energy imparted, due to the generator and/or film shift. When, for example, a conventional single-pulse generator operated at 65kVp tube potential was replaced by a modern constant potential unit, the kV-setting had to be decreased by 5 to 8 kV to maintain the same radiographic contrast. This correction could be done without increasing energy imparted to the patient, taking into account the fact that the spectral characters of the photon energy are not identical. If, in addition, faster intraoral film with lower film contrast was introduced, together with the constant potential unit, the kV-setting had to be further decreased to maintain the radiographic contrast.

Place, publisher, year, edition, pages
1994. Vol. 23, no 2, 83-90 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-21490OAI: oai:DiVA.org:liu-21490DiVA: diva2:241435
Available from: 2009-10-02 Created: 2009-10-02 Last updated: 2009-10-03

Open Access in DiVA

No full text

By organisation
Radio Physics
In the same journal
Dento-Maxillo-Facial Radiology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 15 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf