liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level
Faculty of Engineering Toyama University, Japan.
Faculty of Engineering Toyama University, Japan.
Faculty of Engineering Toyama University, Japan.
Linköping University, The Institute of Technology. Linköping University, Department of Biomedical Engineering, Biomedical Instrumentation. (MINT)ORCID iD: 0000-0002-0012-7867
Show others and affiliations
2004 (English)In: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 42, no 3, 322-327 p.Article in journal (Refereed) Published
Abstract [en]

Development of a non-invasive method for measuring the blood glucose level is an urgent necessity, and putting such a method into practical use will enable some of the physical and mental stress that patients with diabetes have to endure to be removed. To realise a non-invasive blood glucose monitor, the gingival crevicular fluid (GCF) was measured. A GCF-collecting device was developed that was designed to be disposable, biocompatible and small enough to be inserted in the gingival crevice for collection of a sub-microlitre sample of GCF. Also, a high-sensitivity glucose testing tape incorporated in the device was developed. Red laser light in a portable optical device measured the colour density of the testing tape. Standard glucose solutions were used to investigate the measurement accuracy of the GCF glucose monitor and showed a correlation coefficient of R=0.99 (n=20) between the optical density and the glucose levels. The GCF glucose monitor was evaluated on healthy Swedish and Japanese adults (n=10) and both GCF glucose levels (GCFLs) and blood glucose levels (BGLs) were measured in conjunction with meal loads. The GCFLs were about 1/10-1/560 lower than the BGLs. No difference in the range of GCFLs between the Swedish and the Japanese subjects was observed. Therefore it was concluded that physique, body mass index and life-style, such as dietary habit, did not significantly influence the GCFLs. Further, the correlation coefficients of all the subjects were 0.70 and 0.88 with each group. It was suggested that GCF could be used as a method of non-invasive blood glucose measurement.

Place, publisher, year, edition, pages
Springer, 2004. Vol. 42, no 3, 322-327 p.
National Category
Endocrinology and Diabetes
Identifiers
URN: urn:nbn:se:liu:diva-22170DOI: 10.1007/BF02344706ISI: 000222028000007Scopus ID: 2-s2.0-2942720396Local ID: 1300OAI: oai:DiVA.org:liu-22170DiVA: diva2:242483
Available from: 2009-10-07 Created: 2009-10-07 Last updated: 2017-12-13Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Authority records BETA

Wårdell, KarinNyström, Fredrik

Search in DiVA

By author/editor
Wårdell, KarinNyström, Fredrik
By organisation
The Institute of TechnologyBiomedical InstrumentationFaculty of Health SciencesInternal MedicineDepartment of Endocrinology and Gastroenterology UHL
In the same journal
Medical and Biological Engineering and Computing
Endocrinology and Diabetes

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 552 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf