liu.seSearch for publications in DiVA
Change search
ReferencesLink to record
Permanent link

Direct link
A computerized human reference brain for rCBF/SPET technetium-99m exametazime (HMPAO) investigation of elderly
Linköping University, Faculty of Health Sciences. Linköping University, Department of Medicine and Care, Radiation Physics. Östergötlands Läns Landsting, Centre of Surgery and Oncology, Department of Radiation Physics.
Linköping University, Faculty of Health Sciences. Linköping University, Department of Medicine and Care, Medical Radiology. Östergötlands Läns Landsting, Centre for Medical Imaging, Department of Radiology UHL.
Show others and affiliations
2004 (English)In: Clinical Physiology and Functional Imaging, ISSN 1475-0961, Vol. 24, no 4, 196-204 p.Article in journal (Refereed) Published
Abstract [en]

Using the bull's eye approach, a reference brain from the single photon emission tomography (SPET) images of 10 subjects aged 62-81 years with excellent mental and physical health was constructed. SPET images were acquired twice, 1 week apart, using a single detector rotating gamma camera collecting 64 planar images over a 360° orbit. The centre of each transaxial slice was first defined with an automatic edge detecting algorithm applied to an anterior-posterior and a side profile of the brain. Each slice was divided into 40 sectors. Maximum counts/pixel in each sector was picked. The 40 maximum count values from one transaxial slice were allowed to form a horizontal row in a new parametric image on the x-axis and slice number from the vertex to the basal parts of the brain on the y-axis. This new image was scaled to a 64 × 16 pixel matrix by interpolation, which meant a normalization of all studies to the same size. The parametric image in each subject was scaled with regard to intensity by a factor calculated by a normalization procedure using the least squares analysis. Mean and SD for each pixel were calculated, thereby constructing a 'mean parametric image', and a 'SD parametric image'. These two images are meant to be used as the reference brain for evaluation of patient studies. This method can be used for objective measurements of diffuse brain changes and for pattern recognition in larger groups of patients. Statistical multifactorial analysis of parameters used for acquisition and data processing is possible. © 2004 Blackwell Publishing Ltd.

Place, publisher, year, edition, pages
2004. Vol. 24, no 4, 196-204 p.
Keyword [en]
bull's eye, elderly, normal, regional cerebral blood flow, single photon emission tomography, technetium-99m exametazine
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-24634Local ID: 6820OAI: diva2:244956
Available from: 2009-10-07 Created: 2009-10-07 Last updated: 2011-01-12

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Ekberg, StefanSäfström, PiaGranerus, Göran
By organisation
Faculty of Health SciencesRadiation PhysicsDepartment of Radiation PhysicsMedical RadiologyDepartment of Radiology UHLClinical PhysiologyDepartment of Clinical Physiology
In the same journal
Clinical Physiology and Functional Imaging
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 14 hits
ReferencesLink to record
Permanent link

Direct link