Surface plasmon resonance (SPR) analysis of coagulation in whole blood with application in prothrombin time assay
Linköping University, Department of Biomedicine and Surgery, Clinical Chemistry. Linköping University, Faculty of Health Sciences.
Linköping University, Department of Physics, Chemistry and Biology, Applied Physics. Linköping University, Faculty of Health Sciences.
Linköping University, Department of Biomedicine and Surgery, Clinical Chemistry. Linköping University, Faculty of Health Sciences.
Linköping University, Department of Physics, Chemistry and Biology, Applied Physics. Linköping University, The Institute of Technology.
Show others and affiliations
1999 (English)In: Biosensors & bioelectronics, ISSN 0956-5663, E-ISSN 1873-4235, Vol. 14, no 8-9, 671-682 p.Article in journal (Refereed) Published
Abstract [en]

It is previously shown that surface plasmon resonance (SPR) can be used to study blood plasma coagulation. This work explores the use of this technique for the analysis of tissue factor induced coagulation, i.e. prothrombin time (PT) analysis, of whole blood and plasma. The reference method was nephelometry. The prothrombin time analysis by SPR was performed by mixing two volumes of blood/plasma, one volume of thromboplastin, and one volume of CaCl2 solution directly on a sensor surface. The measurements show good agreement between nephelometry and SPR plasma analysis and also between SPR plasma and whole blood analysis. The effect of anticoagulant treatment on the clotting times was significant both quantitatively and qualitatively. The impact on the SPR signal of different physiological events in the coagulation process is discussed, and tentative interpretations of the sensorgram features are given. The major advantage of the SPR method compared to nephelometry is the possibility to perform analysis on whole blood instead of plasma. In conclusion, SPR is a promising method for whole blood coagulation analysis.

Place, publisher, year, edition, pages
1999. Vol. 14, no 8-9, 671-682 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-25062DOI: 10.1016/S0956-5663(99)00050-0Local ID: 9491OAI: oai:DiVA.org:liu-25062DiVA: diva2:245388
Available from: 2009-10-07 Created: 2009-10-07 Last updated: 2012-09-05Bibliographically approved
In thesis
1. Real-time analysis of blood coagulation and fibrinolysis: new rheological and optical sensing techniques for diagnosis of haemostatic disorders.
Open this publication in new window or tab >>Real-time analysis of blood coagulation and fibrinolysis: new rheological and optical sensing techniques for diagnosis of haemostatic disorders.
2001 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The haemostatic system has a dual paradoxical function in the body. It should arrest bleeding whenever needed, but also keep the blood flowing in the circulatory system without any obstructing blood clots. The system is complex with maoy intertwined processes that interact to produce a fine-tuned regulation of the performance. In case of malfunction in this regulation there may be an excessive coagulation ability, thrombophilia, or bleeding tendency, haemophilia. These are common disorders in the Western societies and may be lethal. The long-term airo of this work is therefore to improve the laboratory diagnosis of haemostatic disorders, for thrombophilia in particular. To achieve this goal a global approach has been chosen, meaning that the environment in which a blood sample is analysed should mimic the physiology of the haemostatic system to better elucidate the overall situation in a particular individual. A first attempt to assess the susceptibility for tissue plasminogen activator induced lysis and coagulum structure in plasma as markers for deep vein thrombosis showed promising results with 47% abnormals among the DVT patients included in the study. To improve this assay new sensing techniques were needed, since one of the most important conditions included in a global assay is analysis of whole blood, i.e. blood with all types of blood cells present. Whole blood is opaque and excludes the traditional optical methods that have been used for coagulation analysis. Several candidate techniques have been identified and surface plasmon resonance (SPR), quartz crystal microbalance-dissipation (QCM-D), and free oscillation rheometry (FOR) have been evaluated for haemostatic studies in this thesis. SPR is an optical surface sensitive technique that has showed promising results for measurements in blood plasma during coagulation and fibrinolysis and for whole blood coagulation. The SPR responses were sensitive to treatments with heparin and oral anticoagulants, which are substances used to treat thrombosis. QCM-D that is sensitive to mass deposition and viscoelastic changes in the sample at the quartz crystal surface has been tested in combination with SPR and provided new information about the viscoelastic properties of the coagulum, although with similar sensing depth as SPR. The idea of combined sensing techniques was reconsidered and resulted in a combination of SPR and FOR for siroultaneous real-time measurements in a blood sample. FOR is bulk sensitive and probes rheological changes in the sample. The combination was applied in studies of plasma and whole blood coagulation as well as plasma fibrinolysis. Coagulation studies including chemical surface modifications by using thiol-based self-assembled monolayers were also attempted. Finally, the FOR/SPR combination was found to be sensitive to inhibition of platelet aggregation and blood cell shape changes iroplying that studies on the cellular component of the blood is possible. In conclusion, the combination of FOR and SPR is a promising sensing system for an improved global assay for haemostatic disorders.

Place, publisher, year, edition, pages
Linköping: Linköpings universitet, 2001. 72 p.
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 663
National Category
Medical and Health Sciences
Identifiers
urn:nbn:se:liu:diva-25656 (URN)10032 (Local ID)91-7219-764-1 (ISBN)10032 (Archive number)10032 (OAI)
Public defence
2001-03-16, Berzeliussalen, Universitetssjukhuset, Linköping, 13:00 (Swedish)
Opponent
Available from: 2009-10-08 Created: 2009-10-08 Last updated: 2012-09-05Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Hansson, KennyTengvall, PenttiLundström, IngemarJohansen, KnutLindahl, Tomas

Search in DiVA

By author/editor
Hansson, KennyTengvall, PenttiLundström, IngemarJohansen, KnutLindahl, Tomas
By organisation
Clinical ChemistryFaculty of Health SciencesApplied PhysicsThe Institute of Technology
In the same journal
Biosensors & bioelectronics
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 209 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf