Patient radiation exposure during coronary angiography and intervention
Linköping University, Faculty of Health Sciences. Linköping University, Department of Medicine and Care, Radiology. Östergötlands Läns Landsting, Heart Centre, Department of Cardiology.
Linköping University, Faculty of Health Sciences. Linköping University, Department of Medicine and Care, Radio Physics.
2000 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 41, no 2, 142-144 p.Article in journal (Refereed) Published
Abstract [en]

Purpose: To prospectively register fluoroscopic and cine times in a random fashion, and to measure patient radiation exposure from routine coronary angiography and coronary balloon angioplasty. We also evaluated an optional dose reduction system used during interventions. Material and Methods: The incident radiation to the patient was measured as kerma area product (KAP) in Gycm2, obtained from an ionisation chamber mounted on the undercouch tube during 65 coronary angiography procedures and another 53 percutaneous transluminal coronary angioplasties (including 29 stent procedures), mostly directly following complete coronary angiography. Results and Conclusion: The values from coronary angiography were comparable to other reports with a mean fluoroscopic time of 4.4 min and a mean KAP value of 62.6 Gycm2. The corresponding figures from coronary balloon angioplasty without stenting were lower than otherwise reported, with 8.2 min and 47.9 Gycm2, respectively. The use of coronary stents did prolong the mean fluoroscopic time (10.5 min) but did not significantly enhance the patient mean radiation dose (51.4 Gycm2). The dose reduction technique resulted in a significant KAP value reduction of 57%. In conclusion, with regard to radiation exposure, coronary angiography and balloon angioplasty are considered safe procedures.

Place, publisher, year, edition, pages
2000. Vol. 41, no 2, 142-144 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-26895Local ID: 11519OAI: oai:DiVA.org:liu-26895DiVA: diva2:247445
Available from: 2009-10-08 Created: 2009-10-08 Last updated: 2017-12-13

Open Access in DiVA

No full text

Authority records BETA

Fransson, Sven GöranPersliden, Jan

Search in DiVA

By author/editor
Fransson, Sven GöranPersliden, Jan
By organisation
Faculty of Health SciencesRadiologyDepartment of CardiologyRadio Physics
In the same journal
Acta Radiologica
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 67 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf