Marginal bone reaction to oral implants: A prospective comparative study of Astra Tech and Brσnemark System implants
Linköping University, Faculty of Health Sciences. Linköping University, Department of Neuroscience and Locomotion, Dental Surgery. Östergötlands Läns Landsting, Reconstruction Centre, Department of Oral Surgery UHL.
Show others and affiliations
2002 (English)In: Clinical Oral Implants Research, ISSN 0905-7161, Vol. 13, no 1, 30-37 p.Article in journal (Refereed) Published
Abstract [en]

In earlier studies of Astra Tech and Brσnemark System implants, high survival rates and small marginal bone changes have been demonstrated. The aim of this study was to compare the two systems, primarily with regard to marginal bone changes, but also with regard to other clinical variables of interest. The present paper describes the results after three years. Sixty-six patients were included in the study and randomly assigned to treatment with Astra Tech implants (n = 184) or Brσnemark System implants (n = 187). The marginal bone level was radiographically examined at fixture insertion, at abutment connection, at baseline (delivery of the prosthetic construction) and at 1- and 3-year follow-up examinations. Between fixture insertion and the baseline examination, the pattern of marginal bone resorption differed between the two systems. However, there was no significant marginal bone change between baseline and the 1-year examination or between the 1- and 3-year examinations. Nor were there any differences between the systems. The mean bone loss in the upper jaw between BL (baseline) and 3 years was 0.2▒0.3 mm for Astra Tech implants and 0.2▒0.1 mm for Brσnemark System implants. The corresponding figures for the lower jaw were 0.3▒0.2 mm and 0.2▒0.1 mm. The survival rate of Astra Tech implants was significantly higher (98.9%) than for Brσnemark System implants (95.2%). However, five of the nine implant losses in the Brσnemark group occurred in one patient. For that reason, this result must be interpreted with caution. The number of patients with implant losses did not differ significantly between the systems. Few complications were recorded up to 3 years.

Place, publisher, year, edition, pages
2002. Vol. 13, no 1, 30-37 p.
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-27751DOI: 10.1034/j.1600-0501.2002.130103.xLocal ID: 12495OAI: diva2:248303
Available from: 2009-10-08 Created: 2009-10-08 Last updated: 2011-01-13

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Åstrand, PerFeldmann, Hartmut
By organisation
Faculty of Health SciencesDental SurgeryDepartment of Oral Surgery UHL
In the same journal
Clinical Oral Implants Research
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 19 hits
ReferencesLink to record
Permanent link

Direct link