Oesophageal manometry: design and evaluation of measurement systems
Linköping University, Department of Biomedical Engineering. Linköping University, The Institute of Technology.
1978 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The aim of this study was to investigate the technical characteristics of oesophageal manometry systems and to improve the performance of these systems.

The investigation of the characteristics of oesophageal manometry systems with non-perfused catheters or catheters perfused with a flow generated by a syringe pump did not show properties which fullfilled the requirements for accurate pressure measurements. The bandwidth of the pressure mesurement system was limited by the high compliance of the syringe perfusion pump. The characteristics of perfused systems were improved by the design of a low-compliance perfusion pump. The frequency characteristics of a pressure measurement system utilizing the low-compliance perfusion pump seemed to be determined by the properties of the cathetermanometer system. The frequency content of oesophageal peristaltic pressure was studied by use of a measurement system including the low-compliance perfusion pump. This investigation showed that a bandwidth of about 8 Hz or more is necessary for accurate measurements, which bandwidth can only be obtained with a low-compliance system. In a clinical study a non-perfused system and a system perfused with a syringe pump were compared simultaneously to a system with the low-compliance perfusion pump. The non-perfused system and the system perfused with the syringe pump gave lower peristaltic and sphincter pressure amplitudes than the system with the low-compliance perfusion pump. Since the oesophageal sphincter pressure varies in different radial directions, a pressure transducer has been devised, the mechanical design of which gives an integration of a radial pressure profile. The transducer has a linear static and dynamic transfer function.

Place, publisher, year, edition, pages
Karlshamn: Lagerblads Tryckeri AB , 1978. , 64 p.
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 34Linköping University Medical Dissertations, ISSN 0345-0082 ; 65
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-29492Local ID: 14847ISBN: 91-7372-249-9OAI: diva2:250307
Public defence
1978-12-15, Patologiska institutionens föreläsningssal, Regionsjukhuset, Linköping, 09:00 (Swedish)

Papers, included in the Ph.D. thesis, are not registered and included in the posts from 1999 and backwards.

Available from: 2009-10-09 Created: 2009-10-09 Last updated: 2012-10-22Bibliographically approved

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Ask, Per
By organisation
Department of Biomedical EngineeringThe Institute of Technology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 293 hits
ReferencesLink to record
Permanent link

Direct link