liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Reducing the influence of spatial resolution to improve quantitative accuracy in emission tomography: A comparison of potential strategies
Linköping University, Faculty of Health Sciences. Linköping University, Department of Medicine and Care, Radiation Physics.
Show others and affiliations
2006 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 569, no 2 SPEC. ISS., 462-466 p.Article in journal (Refereed) Published
Abstract [en]

The goal of this paper is to compare strategies for reducing partial volume effects by either minimizing the cause (i.e. improving resolution) or correcting the effect. Correction for resolution loss can be achieved either by modelling the resolution for use in iterative reconstruction or by imposing constraints based on knowledge of the underlying anatomy. Approaches to partial volume correction largely rely on knowledge of the underlying anatomy, based on well-registered high-resolution anatomical imaging modalities (CT or MRI). Corrections can be applied by considering the signal loss that results by smoothing the high-resolution modality to the same resolution as obtained in emission tomography. A physical phantom representing the central brain structures was used to evaluate the quantitative accuracy of the various strategies for either improving resolution or correcting for partial volume effects. Inclusion of resolution in the reconstruction model improved the measured contrast for the central brain structures but still underestimated the true object contrast (∼0.70). Use of information on the boundaries of the structures in conjunction with a smoothing prior using maximum entropy reconstruction achieved some degree of contrast enhancement and improved the noise properties of the resulting images. Partial volume correction based on segmentation of registered anatomical images and knowledge of the reconstructed resolution permitted more accurate quantification of the target to background ratio for individual brain structures. © 2006 Elsevier B.V. All rights reserved.

Place, publisher, year, edition, pages
2006. Vol. 569, no 2 SPEC. ISS., 462-466 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-36823DOI: 10.1016/j.nima.2006.08.143Local ID: 32692OAI: oai:DiVA.org:liu-36823DiVA: diva2:257672
Available from: 2009-10-10 Created: 2009-10-10 Last updated: 2017-12-13

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Olsson, Anna

Search in DiVA

By author/editor
Olsson, Anna
By organisation
Faculty of Health SciencesRadiation Physics
In the same journal
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 43 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf