Fixed or loose? Dichotomy in RSA data for cemented cups
Linköping University, Faculty of Health Sciences. Linköping University, Department of Clinical and Experimental Medicine, Orthopaedics and Sports Medicine . Östergötlands Läns Landsting, Orthopaedic Centre, Department of Orthopaedics Linköping.
Swedish National Competence Center for Musculoskeletal Disorders Lund University Hospital.
Department of Orthopedics Umeå University Hospital.
Swedish National Competence Center for Musculoskeletal Disorders Lund University Hospital.
2008 (English)In: Acta Orthopaedica, ISSN 1745-3674, Vol. 79, no 4, 467-473 p.Article in journal (Refereed) Published
Abstract [en]

BACKGROUND AND PURPOSE: Roentgen stereometric analysis (RSA) cannot discern whether a single prosthesis is fixed or migrating below the detection level. Samples of patients usually show migration values that appear to be continuously distributed. Is there such continuity, or is there a dichotomy between stable and migrating prostheses? The hypothesis of a dichotomy has, to our knowledge, not been tested. We present an exploratory evaluation of such a dichotomy using a mixture distribution algorithm. METHODS: We analyzed the migration (as determined by RSA) of 147 cemented acetabular cups of 7 different designs by using a new set of algorithms for frequency distribution analysis called Rmix. RESULTS: We first analyzed a migration vector, regardless of direction. After 2 years there was a significant dichotomy between 2 lognormal subgroups within the sample. Although some types of cups were over-represented in one of the subgroups, neither cup design, sex, nor operating department could explain the dichotomy into two groups, which appears to reflect the existence of two basically different types of behavior of the cups. We next analyzed the migration along the 3 axes in space, and found a similar dichotomy. During the second year, around 80% of the patients belonged to a distinct, normally distributed subgroup with a mean not different from 0 mm and a small variation. The remainder differed significantly from this subgroup and showed migration. INTERPRETATION: There is a dichotomy in migration pattern. During the second postoperative year, most cups belonged to a subpopulation that appeared stable. The remainder is probably at risk of loosening. For a single type of prosthesis, the relative size of the stable subgroup may be a good index of the expected performance. The possibility of detecting subgroups within a seemingly continuous sample might be useful in many fields of medicine.

Place, publisher, year, edition, pages
2008. Vol. 79, no 4, 467-473 p.
Keyword [en]
Acetabulum/*radiography Aged Aged, 80 and over Algorithms Arthroplasty, Replacement, Hip/*adverse effects/methods Cementation Female Hip Prosthesis/adverse effects Humans Male Middle Aged Photogrammetry Prosthesis Design *Prosthesis Failure
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-43150DOI: 10.1080/17453670710015445Local ID: 72085OAI: diva2:264008
Available from: 2009-10-10 Created: 2009-10-10 Last updated: 2011-01-10

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Aspenberg, Per
By organisation
Faculty of Health SciencesOrthopaedics and Sports Medicine Department of Orthopaedics Linköping
In the same journal
Acta Orthopaedica
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 12 hits
ReferencesLink to record
Permanent link

Direct link