Simultaneous estimation of muscle fibre conduction velocity and muscle fibre orientation using 2D multichannel surface electromyogram
Grönlund, C., Dept. of Biomedical Eng./Informatics, University Hospital, Umeå, Sweden, Ctr. for Biomed. Engineering/Physics, Umeå University, Umeå, Sweden.
Linköping University, Faculty of Health Sciences. Linköping University, Department of Clinical and Experimental Medicine, Rehabilitation Medicine .
Human Movement Sciences Program, Norwegian Univ. of Sci./Technology, Trondheim, Norway.
Dept. of Biomedical Eng./Informatics, University Hospital, Umeå, Sweden, Ctr. for Biomed. Engineering/Physics, Umeå University, Umeå, Sweden.
2005 (English)In: Medical and Biological Engineering and Computing, ISSN 0140-0118, Vol. 43, no 1, 63-70 p.Article in journal (Refereed) Published
Abstract [en]

The paper presents a new approach for simultaneous estimation of muscle fibre conduction velocity (MFCV) and muscle fibre orientation (MFO) for motor units (MUs) in two-dimensional (2D) multichannel surface electromyography recordings. This is an important tool for detecting changes and abnormalities in muscle function and structure. In addition, simultaneous estimation of MFO and MFCV avoids the necessity of manual electrode alignment. The proposed method detected propagating MU action potentials (MUAPs) in a running time window as moving components in amplitude maps. Thereafter, estimations were obtained by fitting a three-dimensional function to these maps. The performance was evaluated using synthetic MU signals at 10 dB SNR and authentic biceps brachii measurements. Results demonstrated MFCV and MFO estimates with standard deviations of less than 0.05 m s-1 and 1° for simulated signals, and less than 0.2 m s-1 and 4° for experimental data. However, standard deviations as low as 0.12 m s-1 and 1.6° from real signals were demonstrated. It was concluded that the method performs as well as, or better than, linear array multichannel methods when individual propagating MUAPs can be identified, even if electrodes are not aligned with fibre direction. © IFMBE 2005.

Place, publisher, year, edition, pages
2005. Vol. 43, no 1, 63-70 p.
Keyword [en]
Conduction velocity, EMG, Fibre orientation, Motor unit, Multichannel, Surface electromyography
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-45531DOI: 10.1007/BF02345124OAI: oai:DiVA.org:liu-45531DiVA: diva2:266427
Available from: 2009-10-11 Created: 2009-10-11 Last updated: 2011-01-12

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Östlund, Nils

Search in DiVA

By author/editor
Östlund, Nils
By organisation
Faculty of Health SciencesRehabilitation Medicine
In the same journal
Medical and Biological Engineering and Computing
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 27 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf