INR calibration of Owren-type prothrombin time based on the relationship between PT% and INR utilizing normal plasma samples
Linköping University, Faculty of Health Sciences. Linköping University, Department of Clinical and Experimental Medicine, Clinical Chemistry.
Karolinska Hospital.
Malmö University Hospital.
Aker University Hospital.
Show others and affiliations
2004 (English)In: Thrombosis and Haemostasis, ISSN 0340-6245, Vol. 91, no 6, 1223-1231 p.Article in journal (Refereed) Published
Abstract [en]

Prothrombin time (PT) is clinically important and is used to monitor oral anticoagulant therapy. To obtain PT results in international normalized ratio (INR), the current standardization procedure is complex and involves reference reagents. The PT of diluted plasma samples can be determined with a combined thromboplastin (the Owren-type procedure), but not necessarily with a plain thromboplastin (the Quick-type procedure). Owren-type PT procedures can therefore, as an alternative to the INR calibration, be calibrated with diluted normal plasma to give PT results in percent of normal PT activity (PT%). The present study explored if a plasma-based calibration of an Owren-type PT procedure can be used to obtain results in INR. The approach was to establish a relationship between PT% and INR by multi-center analysis of 365 samples from healthy individuals and patients on warfarin treatment. INR values were obtained by manual Quick-type reference procedure and PT% values by various automated Owren-type procedures. A relationship INR = (I/PT% + 0.018)10.028 was found. A calibration procedure, based on the relationship, was investigated. Calibrators were the median PT of 21 normal plasma at dilutions representing 100%, 50%, 25%, 12.5% and 6.25% of normal PT activity. These were assigned INR values of 1.00, 1.36, 2.07, 3.05 and 6.36. Calibration of various Owren-type assays was repeatedly performed by 5 expert laboratories during 3 consecutive years. The INR values of certain lyophilised or frozen control plasmas were determined. The frozen control plasmas had externally assigned INR values according to WHO guidelines. Within the laboratory, CV was typically below 3%. No appreciable difference among the results of the different laboratories or the three assay occasions was found. Externally assigned and INR values were essentially identical to those found. These and other results indicated that the calibration procedure was reproducible, precise and accurate. Thus, an Owren-type PT assay can be calibrated with normal plasma samples to give results in INR and the investigated calibration procedure can be proposed for this purpose.

Place, publisher, year, edition, pages
2004. Vol. 91, no 6, 1223-1231 p.
Keyword [en]
calibration, international normalized ratio, oral anti coagulation, prothrombin time, thromboplastin
National Category
Medical and Health Sciences
URN: urn:nbn:se:liu:diva-46220DOI: 10.1160/TH03-07-0456OAI: diva2:267116
Available from: 2009-10-11 Created: 2009-10-11 Last updated: 2011-12-19

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Lindahl, TomasRånby, M
By organisation
Faculty of Health SciencesClinical ChemistryDepartment of Clinical Chemistry
In the same journal
Thrombosis and Haemostasis
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 38 hits
ReferencesLink to record
Permanent link

Direct link