Net Pressure Gradients in Aortic Prosthetic Valves can be Estimated by Doppler
Department of Clinical Physiology, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden.
Gjertsson, P..
Department of Clinical Physiology, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden.
Linköping University, Faculty of Health Sciences. Linköping University, Department of Medical and Health Sciences, Clinical Physiology. Östergötlands Läns Landsting, Heart Centre, Department of Clinical Physiology.
Show others and affiliations
2003 (English)In: Journal of the American Society of Echocardiography, ISSN 0894-7317, E-ISSN 1097-6795, Vol. 16, no 8, 858-866 p.Article in journal (Refereed) Published
Abstract [en]

Background: In aortic prosthetic valves, both the Doppler-estimated gradients and orifice areas are misleading in the assessment of hemodynamic performance. The parameter of major interest is the net pressure gradient after pressure recovery (PR). We, therefore, investigated, in vitro, our ability to predict the net pressure gradient and applied the formulas in a representative patient population with 2 different valve designs. Methods: We studied the St Jude Medical (SJM) standard valve (size 19-27) and SJM Biocor (size 21-27) in an in vitro steady-flow model with simultaneous Doppler-estimated pressure and catheter pressure measurements. Using echocardiography, we also studied patients who received the SJM (n = 66) and SJM Biocor (n = 45). Results: In the SJM, we observed PR both within the prosthesis and aorta, whereas in the SJM Biocor, PR was only present in the aorta. We estimated the PR within the valve and within the aorta separately from echocardiographic in vitro data, combining a regression equation (valve) with an equation on the basis of fluid mechanics theory (aorta). The difference between estimated and catheter-obtained net gradients (mean ± SD) was 0.6 ± 1.6 mm Hg in the SJM and - 0.2 ± 1.9 mm Hg in the SJM Biocor. When these equations were applied in vivo, we found that PR had an overall value of 57 ± 7% of the peak Doppler gradient in the SJM and 33 ± 9% in the SJM Biocor. Conclusions: The in vitro results indicate that it is possible to predict the net pressure gradient by Doppler in bileaflet and stented biologic valves. Our data indicate that important PR is also present in stented biologic valves.

Place, publisher, year, edition, pages
2003. Vol. 16, no 8, 858-866 p.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:liu:diva-46533DOI: 10.1067/S0894-7317(03)00422-XPubMedID: 12878995OAI: oai:DiVA.org:liu-46533DiVA: diva2:267429
Available from: 2009-10-11 Created: 2009-10-11 Last updated: 2017-12-13

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Wranne, BengtAsk, PerLoyd, Dan

Search in DiVA

By author/editor
Wranne, BengtAsk, PerLoyd, Dan
By organisation
Faculty of Health SciencesClinical PhysiologyDepartment of Clinical PhysiologyPhysiological MeasurementsThe Institute of TechnologyApplied Thermodynamics and Fluid Mechanics
In the same journal
Journal of the American Society of Echocardiography
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 600 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf