liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Legionella pneumophila serogroup 1 antibody kinetics in patients with Legionnaires' disease: implications for serological diagnosis
Department of Infectious Diseases, Ryhov Hospital, Jönköping, Sweden.
Department of Clinical Bacteriology, Ryhov Hospital, Jönköping, Sweden.
Department of Infectious Diseases, Ryhov Hospital, Jönköping, Sweden.
Department of Infectious Diseases, Ryhov Hospital, Jönköping, Sweden.
Show others and affiliations
2003 (English)In: Scandinavian Journal of Infectious Diseases, ISSN 0036-5548, E-ISSN 1651-1980, Vol. 35, no 1, p. 15-20Article in journal (Refereed) Published
Abstract [en]

To evaluate current serological criteria for Legionella pneumophila serogroup 1 (Lp1), the antibody response was prospectively studied in all patients hospitalized for Legionnaires' disease in a Swedish county during 11 y (n = 62). A 4-fold or greater rise in antibody titre to ≥ 128 (the minimum convalescent antibody level for diagnosis, as recommended by the Centers for Disease Control and Prevention), using the indirect immunofluorescence antibody test, was found in 21/52 (40%) of tested patients. By referring to the titre levels in healthy residents from the local population (World Health Organization criteria), 45/52 (87%) cases were confirmed serologically. In 21 patients followed longitudinally for 10 y, the median antibody titre fell from 256 (range 32-1024) to 16 (range 2-128) in 3 y. No booster reactions were observed in any patient. After 10 y, the geometric mean titre of this clinical cohort had reached the same level as observed in the background population 5 y earlier. Titre levels in subjects exposed to Legionella from a municipal water system indicate that only 1 out of 10 of all infections are identified clinically. Indirect immunofluorescent antibody testing with local reference sera is a sensitive method for laboratory confirmation of Lp1 in an unselected pneumonia population.

Place, publisher, year, edition, pages
2003. Vol. 35, no 1, p. 15-20
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:liu:diva-46696DOI: 10.1080/0036554021000026998OAI: oai:DiVA.org:liu-46696DiVA, id: diva2:267592
Available from: 2009-10-11 Created: 2009-10-11 Last updated: 2017-12-13Bibliographically approved
In thesis
1. Epidemiology and long term control of nosocomial legionnaires' disease
Open this publication in new window or tab >>Epidemiology and long term control of nosocomial legionnaires' disease
2003 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The first nosocomial legionella outbreak in a Scandinavian general district hospital was identified in an epidemiological investigation of a cluster of pneumonia cases in Värnamo in 1991. During 3 months, 28 patients and 3 staff fell ill and 3 died. Legionella pneumophila serogroup (sg) 1, was found in high counts throughout the hospital hot water system and was probably spread by aerosolisation via shower nozzles. The outbreak was arrested when the circulating hot water temperature was raised from <45°C to >55°C.

The nosocomial infections proved to be part of a wider legionella outbreak and 10 cases contracted outside the hospital were also detected. Legionellae were cultured from 7 of 15 community buildings and 31% (109/354) of subjects living in the Värnamo area had an elevated titre (≥6) to L. pneumophila sg 1 in 1991, indicating a temporary spread of legionella in the community. Subclinical infection was demonstrated and it was estimated that only 10% of all infections had been clinically identified. Nosocomial legionnaires' disease should alert physicians to possible legionella transmission in the community.

In 21 patients from the nosocomial outbreak, the median L. pneumophila sg 1 antibody titre fell from 1:256 to 1:16 in 3 years. After 10 years, the titre level in this clinical cohort had reached the same level as observed in the background population 5 years earlier. Current international serological criteria (a fourfold or greater rise in antibody titre to ≥1:128) identified only 40% (21/52) of pneumonia cases caused by L. pneumophila sg 1 in a Swedish population in 1991-2001. When the antibody response was related to the antibody titre in local residents, the sensitivity rose to 87% (45/52).

Keeping the circulating hospital hot water temperature above 55°C, and vigilant clinical surveillance of nosocomial pneumonia as a method for control of nosocomial legionnaires' disease was evaluated after 10 years of practice. Infection with L. pneumophila sg 1 was diagnosed in 4 out of 366 (1.1 %) patients treated for nosocomial pneumonia, representing 1 case per 26,000 admissions. All patients were cured without complications. L. pneumophila sg 1 was isolated in 30 of 251 (12%) cultured hospital water samples during the monitoring period. It was concluded that this approach was safe and effective for long term control of nosocomial legionnaires' disease in a primary referral hospital.

The hospital hot water system was found to be colonised with a single genotype of L. pneumophila sg 1 over a 12-year period. The same genotype, identified using amplified fragment length polymorphism (AFLP) analysis, was also demonstrated in 18/20 (90%) community isolates. The phenotypic variation was confined to the monoclonal antibody subtypes Benidorm and Bellingham. The hospital genotype was identified in 2 out of 6 Swedish hospitals, both located within 100 km of Värnamo. Obviously, an entire municipal water network may constitute a distinct ecological niche for a single legionella strain. Certain clones also seem to be widely spread in the environment. This implies that results from molecular subtyping must be interpreted cautiously in epidemiological investigations of legionnaires' disease.

Place, publisher, year, edition, pages
Linköping: Linköpings universitet, 2003. p. 88
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 814
National Category
Medical and Health Sciences
Identifiers
urn:nbn:se:liu:diva-26648 (URN)11213 (Local ID)91-7373-497-7 (ISBN)11213 (Archive number)11213 (OAI)
Public defence
2003-10-24, Föreläsningssalen, Qulturum, Hus B4, Länssjukhuset Ryhov, Jönköping, 13:00 (Swedish)
Opponent
Available from: 2009-10-08 Created: 2009-10-08 Last updated: 2023-03-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Darelid, JohanBriheim, Gunnar

Search in DiVA

By author/editor
Darelid, JohanBriheim, Gunnar
By organisation
Infectious DiseasesFaculty of Health Sciences
In the same journal
Scandinavian Journal of Infectious Diseases
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 237 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf