A multielement RF coil for MRI guidance of interventional devices
Surgical Planning Laboratory, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States, Surgical Planning Laboratory, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St., Boston, MA 02115, United States.
Linköping University, Faculty of Health Sciences. Linköping University, Department of Medicine and Health Sciences, Clinical Physiology . Östergötlands Läns Landsting, Heart Centre, Department of Clinical Physiology.
Show others and affiliations
2001 (English)In: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, Vol. 14, no 1, 56-62 p.Article in journal (Refereed) Published
Abstract [en]

Accurate localization of minimally invasive devices is critical to the success of interventional procedures. Device orientation and tip position are two of the most important pieces of information needed to define device location for magnetic resonance imaging (MRI)-guided interventional procedures. While a single one-element micro coil incorporated into an interventional device has proven to be effective in some applications, it can only supply tip position information. However, multiple positions on the device are necessary to also determine its orientation. For this purpose, a novel single micro coil design with three separate winding elements that provides both the device orientation and tip position is described in this study. Definition of MR scan planes, by using the device orientation and the target tissue location, permits automatic tracking of the insertion of the device. Furthermore, devices that include this coil design are permitted to bend to a limited extent. This makes the micro coil design appropriate for many flexible interventional devices. Reliable near-real-time tracking of three points on an interventional device is demonstrated on a 0.2T MRI system with modest gradient performance. Phantom and in vivo animal experiments are used to demonstrate the utility of this new coil design. © 2001 Wiley-Liss, Inc.

Place, publisher, year, edition, pages
2001. Vol. 14, no 1, 56-62 p.
Keyword [en]
Device visualization, Interventional MRI, Micro RF coil design, MR guidance, Tip tracking
National Category
Engineering and Technology
URN: urn:nbn:se:liu:diva-47315DOI: 10.1002/jmri.1151OAI: diva2:268211
Available from: 2009-10-11 Created: 2009-10-11 Last updated: 2013-08-28

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Wigström, LarsKnutsson, Hans
By organisation
Faculty of Health SciencesClinical Physiology Department of Clinical PhysiologyThe Institute of TechnologyMedical Informatics
In the same journal
Journal of Magnetic Resonance Imaging
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 529 hits
ReferencesLink to record
Permanent link

Direct link